USER AND SAFETY INSTRUCTIONS
1.1 Safety instructions
The installation instructions are part of your inVENTer Connect controller platform and must be
available at all times (see www.inventer.de/downloads). When handing the system to a third party,
the information regarding access to the installation instructions must be handed over also.
Before performing any work on the system, read the installation instructions carefully and observe
all notices that refer to the assembly and installation process in this section. Also note the safety
instructions that precede the described handling instructions.
Non-observance of safety instructions could result in injury and/or property damage.
Intended use
The inVENTer Connect controller platform may only be used to control the decentralised iV ven-
tilation devices with heat recovery (iV-Smart+, iV14-Zero, iV-Light or iV-Compact product series,
each equipped with the Connect inner cover) from inVENTer GmbH.
Specifically, the following must be used:
• The Easy Connect e16 controller to control the devices included in the system.
• The Connect inner cover controlled by the controller to control the inVENTer ventilation devices
with heat recovery.
• The sensor system is paired to the controller (FTS19-Connect Indoor/Outdoor humidity/tem-
perature sensor, CS2-Connect CO
2
sensor and SK19-Connect switching contact) to supply
temperature, humidity and CO
2
values to the Easy Connect e16 controller, which in turn uses
these values to control the inVENTer ventilation devices with heat recovery.
Requirements for intended use:
•
When installing, ensure compliance with the applicable building regulations, fire protection
regulations and accident prevention regulations of the relevant professional association.
• Use the devices integrated into the ventilation system only in accordance with the applications
that are described in this documentation and only in conjunction with devices that are
recommended, approved and named by inVENTer GmbH in this documentation.
Changes or modifications to the devices are not permitted.
• In particular, use the FTS19-Connect Indoor humidity/temperature sensor exclusively to meas-
ure the humidity and temperature of indoor air, the FTS19-Connect Outdoor humidity/tempera-
ture sensor to measure the humidity and temperature of outdoor air, the CO
2
sensor exclusively
to measure the carbon dioxide content as well as the temperature and humidity of indoor air
and the SK19-Connect switching contact exclusively to integrate safety devices while simulta-
neously operating the ventilation system with fireplaces and all four only in conjunction with the
Easy Connect e16 controller. Changes or modifications to sensors and switching contacts are
not permitted.
• Trouble-free and safe operation of the system depends upon proper transportation, proper
storage and installation as well as careful operation and maintenance.
• These installation instructions are
only
valid
in conjunction with the installation and oper-
ating instructions of the corresponding ventilation device
with Connect compatibility and
supplement these.
All legal notices that are listed in the respective installation instructions also apply without
restriction to this document.