28
inVENTer Connect controller platform | Installation instructions
PREPARING FOR INSTALLATION
Installing the inner cover housing
The installation of the housing is described here on the basis of the flush-mounted housing.
The surface-mounted housing is mounted on the inside wall in the same way.
DANGER
Exposed electrical components.
Electric shock and injury due to live components (230V, 50Hz)!
•
Before working on electrical installations, disconnect all affected equipment from the power
supply.
• Secure the system against being switched on again.
Spirit level, pencil, drill, cordless screwdriver, screws, dowels
Requirements:
• The wall sleeve is installed.
• The cables are laid.
►
Remove the protective cover from the housing.
►
Place the housing centred around the wall sleeve
on the inside wall.
The centring spigot of the flush-mounted
box is inserted over the wall sleeve and lies
flush against the stop.
►
Align the housing using a spirit level.
►
Mark the four corner drill holes.
►
Drill the four holes with Ø 6 mm, min. 40 mm deep.
►
Insert the dowels into the holes.
!