inVENTer Connect controller platform | Installation instructions
INSTALLING THE DEVICES
Installation accessories and installation dimensions
Designation
Width [mm]
Height [mm]
Depth [mm]
FTS19-Connect Indoor humidity/temperature sensor
Base plate
56
56
2
Housing
60
60
22
Separating the base plate from the housing
First separate the base plate from the housing. To do this, unlock the snap-in connection.
Small slotted screwdriver
Requirements:
• The Indoor humidity/temperature sensor is un-
packed and shows no signs of transport or other
damage.
►
Insert a small screwdriver into the narrow opening
on the underside of the Indoor humidity/temperature
controller.
►
Carefully press the locking hook that can be
reached in this way upwards ( ) until it disengages
from its anchorage.
►
Swivel the housing away from the base plate ( )
and lift the upper hooks of the housing out of the
eyelets on the base plate.
►
Remove the housing from the base plate.
The housing and base plate are separate.
2
2
1
1