Top End
®
Terminator™Series
Camber Tube with Single Camber
1.
If necessary, open both camber clamps.
2.
Using an "L" square
A
, rotate the axle tube until the flat edge
of the camber tube
D
is at a 90° angle
B
with the ground/floor
C
as shown.
3.
Close both camber clamps.
4.
Determine the toe in/toe out of the wheelchair.
Adjustable Camber System
–
Before performing this procedure, make sure the
camber inserts are positioned to the lowest degree
of camber.
1.
If necessary, open both camber clamps
A
.
2.
Loosen the set screw that secures each toe adjustment ring
B
to the axle tube
D
.
3.
Using an "L" square, rotate the axle tube until the flat edge of the
camber insert is at a 90° angle with the ground/floor as shown.
4.
Close the right camber clamp.
5.
Rotate the Left toe adjustment ring
B
until the tab stops against
the Lower metal tab on the camber clamp.
6.
Securely tighten set screw on left toe adjustment ring
B
.
7.
Measure the distance between the center lines at the rear and
front of the rear wheels at approximately 12 inches (30.48 cm)
from the ground/floor.
8.
Perform one of the following:
•
Toe In/Toe Out Measurement is Within ±1/8-inch (0.32
cm) - Proceed to step 9.
•
Toe In/Toe Out Measurement is Not Within ±1/8-inch (0.32
cm) - Repeat steps 1-7 until toe in/toe out measurement is
within ±1/8 inch (0.32 cm).
9.
Open the right camber clamp
A
.
10. Reposition the camber inserts to the highest degree of camber.
11. Repeat step 3.
12. Close the left camber clamp
A
.
13. Rotate the right toe adjustment ring
B
until the tab stops against
the upper metal tab on the camber clamp
A
.
14. Securely tighten set screw on right toe adjustment ring
B
.
15. Repeat step 7.
16. Perform one of the following:
•
Toe In/Toe Out Measurement is Within ±1/8-inch (0.32
cm) - Proceed to step 17.
•
Toe In/Toe Out Measurement is Not Within ±1/8-inch
(0.32 cm)
a.
Repeat step 1.
b.
Loosen the set screw on the right toe adjustment ring
B
.
c.
Repeat step 3.
d.
Repeat steps 12-16 until toe in/toe out measurement is
within ±1/8 (0.32 cm) inch.
17. If desired, reposition camber inserts to the desired degree of
camber.
44