background image

292

PO

S  AVE  THESE  INSTRUCTIONS

(292PO)  BUBBLE SPA WITH POOL  ENGLISH  7.5” X 10.3”  PANTONE 295U  01/26/2016

English

Page 21

Spa Tub Cleaning

If dirt is visible in the water or water becomes cloudy and proper water chemistry does not clear it up, change 
the water and clean the spa tub. See “Spa Tub Drainage” section on how to drain the spa.
While empty, remove the cartridge housing from inside of the spa tub wall, clean and/or replace the filter 
cartridge. Use a sponge and mild soap solution to wipe away any soil or stains on the inside of the spa wall. 
Rinse thoroughly before refilling with clean water.

IMPORTANT: 

Do not use steel wool, hard brushes or abrasive cleaners.

Spa Tub Air Valve Fastening

Check the spa tub air valve for leakage and tightness before use. If air is leaking from the air valve, use the 
provided wrench 

(22) 

to tighten the air valve as follow:

1.

  Make sure the spa tub is deflated, open the air valve cap 

and insert the wrench 

(22)

 into the air valve body

 (see 

drawing 23).

2.

  With one hand, hold the backside of the air valve base 

from the inside of the spa tub wall and turn the wrench

  

(22) 

clockwise.

 

IMPORTANT:

 Never adjust the air valve base when the 

spa is in use or filled with water. Only use the air valve 
wrench if the air valve is loose or there is leakage around 
air valve base. Do not over tighten the air valve: over 

 

tightening can damage the valve. Just ensure the air valve is snug and not leaking.

Spa Cover

The attachment buckles of the cover are locking buckles. Two keys are provided in the plastic bag with the 
manual and other accessories. Each buckle is marked with “locked” and “unlocked” symbols for easy operation: 
put the key into the slot on the buckle and turn it to the appropriate position to lock or unlock the buckle 
respectively. 
To assure safety from unauthorized access, always put the cover on when spa is not in use and lock all buckles. 
Always keep the keys out of reach of children. In case you misplace the keys, you can use any similar size flat 
screwdriver to lock or unlock the buckles. 
Inspect the spa cover regularly for leaks, premature wear and tear, damage, or signs of deterioration. Never use 
a worn or damaged cover: it will not provide the level of protection required to prevent unsupervised access to 
the spa by a child.

MAINTENANCE (continued)

23

22

Summary of Contents for PureSpa PS-BH-10

Page 1: ...d boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates...

Page 2: ...ncy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a...

Page 3: ...ided for this purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not us...

Page 4: ...timers plug adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your ha...

Page 5: ...ge 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not...

Page 6: ...294 10 SPA DRAIN PLUG 1 11696B 11 SPA DRAIN VALVE ADAPTOR 1 11713 12 FILTER CARTRIDGE HOUSING 4 11798 13 FILTER CARTRIDGE 4 11692 14 FILTER CARTRIDGE HOUSING LID 4 11797 15 INLET OUTLET PLUG 6 11739 1...

Page 7: ...apacity 310 gal 1 173 L Inner outer size 152 3 86M 72 1 83M 50 1 27M 72 1 83M 52 1 32M 106 2 69M B A Height 28 in 71 cm Bubble air blower 1 1 HP 110 120 V 60 Hz Filter pump flow rate 323 gal hr 1 222...

Page 8: ...cilitate draining purposes during long term spa storage Make sure the floor is water resistant and non slip surface Do not install the spa on carpet or other materials that will be damaged by moisture...

Page 9: ...onal print copies Laminate the printed safety sign copy for protection from the elements Spa Control Unit Assembly 1 Connect the control panel 3 cable plug into the receptacle on top of the spa contro...

Page 10: ...it see drawing 7 3 Unscrew the air valve cap to reveal the stem in the up position for inflation Insert the other end of the inflation hose 7 into the valve and turn to the right to lock it in positio...

Page 11: ...it is firm to the touch but not hard see drawing 13 2 Disconnect the inflation hose 7 from the air blower inflation outlet and the valve 3 Replace the control base inflation cap 5 back close and rece...

Page 12: ...m the spa outlets before spa usage see drawing 17 Re attach them after usage for water filtration and cleaning 4 Before filling with water make sure the bottom drain valve caps are securely closed on...

Page 13: ...e following options are available During the heating process press the filter button for 3 seconds to switch the filtration function to the B side the heater will stop and the flame icon will turn off...

Page 14: ...ivated the filtration system will automatically start The filtration system can be activated together with the bubble function When the indicator light B is illuminated and the heater is off press the...

Page 15: ...at up the water to the desired temperature Press the temperature increase button to set the desired water temperature If problem persists contact Intex Service center E95 Water temperature too high Tu...

Page 16: ...g assembly back onto the spa tub wall 2 Change the spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections fo...

Page 17: ...ion of total alkalinity Result if too high Scale formation cloudy water shorter filter heater runs eye skin irritation poor chlorine efficiency Total Alkalinity TA indicates the degree of the water s...

Page 18: ...0 ppm you can add sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriati...

Page 19: ...ppm 350 ppm 250 ppm Desired level 100 ppm Water Volume Ratio Vhard water Vsoft water 1 9 1 4 2 5 2 3 Lowering Calcium Hardness Using Soft Water Raising pH Raising pH Using Sodium Bicarbonate Lowering...

Page 20: ...stops draining disconnect the spa control unit from the spa tub wall Lift the spa tub wall from the side opposite the drain leading any remaining water to the drain and emptying the spa completely se...

Page 21: ...he inside of the spa tub wall and turn the wrench 22 clockwise IMPORTANT Never adjust the air valve base when the spa is in use or filled with water Only use the air valve wrench if the air valve is l...

Page 22: ...nction is activated to avoid damage to the blower motor 4 Make sure all the spa components and accessories are thoroughly clean and dry before storage Air dry the spa tub in the sun for an hour before...

Page 23: ...vide a dedicated circuit breaker feeding the spa electrical outlet only Contact a qualify electrician to correct the electrical fault Increase the temperature and attach the spa cover Clean or replace...

Page 24: ...rmal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be s...

Reviews: