background image

292

PO

S  AVE  THESE  INSTRUCTIONS

(292PO)  BUBBLE SPA WITH POOL  ENGLISH  7.5” X 10.3”  PANTONE 295U  01/26/2016

English

Page 4

j)  Exit immediately if uncomfortable, dizzy, or sleepy. Spa heat can cause hyperthermia and unconsciousness.  

  The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. The causes,   

  symptoms, and effects of hyperthermia may be described as follows:

  Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the  

  normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the 

  internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia

  include failure to perceive heat; failure to recognize the need to exit spa or hot tub; unawareness of 

  impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub; and 

  unconsciousness resulting in the danger of drowning.

•  People with infectious diseases should not use a spa or hot tub.

•  To avoid injury exercise care when entering or existing the spa or hot tub.

•  Always add chemicals to water, never add water to chemicals. Adding water to chemicals may cause    

  strong fumes or violent reactions and hazardous chemical spray.

•  Never jump or dive into a spa or any shallow body of water.

•  Assembly and disassembly by adults only.

•  Always unplug this product from the electrical outlet before removing, cleaning, servicing or making any    

  adjustment to the product.

•  The plug must be accessible after product is installed.

•  Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers, hedge    

  trimmers and other equipment.

•  If the supply cord is damaged, it must be replaced by a qualified electrician in order to avoid a hazard. Use  

  only identical replacement parts when servicing.

•  To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or converter plugs to  

  connect unit to electrical supply; provide a properly located outlet.

•  Do not attempt to plug in or unplug this product while standing in water or when your hands are wet.

•  Do not leave the spa empty for extended period of time. Do not expose the spa under direct sunshine.

•  Adequate drainage system must be provided around the spa to deal with overflow water.

•  Do not allow the water in the spa to freeze. Do not turn on the spa when the water is frozen.

•  Do not use the spa if damaged in delivery and/or malfunctioning in any fashion. Contact the Intex service  

  center for further direction.

•  Never pour water with a temperature higher than 104°F (40°C) into the spa directly.

•  Keep all pets away from spa to avoid any damage.

•  Do not add bath oil or bath salt to the spa water.

WARNING

CAUTION

•  Maintain water chemistry in accordance with manufacturer’s instructions.

•  This product is provided with a GFCI/RCD located at the end of the power cord. The GFCI/RCD must be  

  tested before each use. Do not use the spa if the GFCI/RCD does not function properly. Disconnect the

  power cord until the fault has been identified and corrected. Contact a qualified electrician to correct the   

  fault. Do not bypass the GFCI/RCD. There are no serviceable parts inside the GFCI/RCD. Opening the    

  GFCI/RCD will void the warranty.

1.

  Plug the power cord into a grounded electrical socket.

2.

  Press the 

RESET

 button on the GFCI/RCD

.

 

3.

  Turn on the spa electrical equipment.

4.

  Press the 

TEST

 button on the GFCI/RCD

.

 

The GFCI/RCD indicator 

  should turn off and the electrical equipment should shut off. If the 

  GFCI/RCD indicator does not turn off, and the electrical equipment 

  does not shut off, the GFCI/RCD is faulty. Do not use the spa. 

  Contact a qualified electrician to correct the fault.

5.

  Press the 

RESET

 button on the GFCI/RCD. The indicator on 

  the GFCI/RCD should turn on. If the GFCI/RCD indicator does 

  not turn on, the GFCI/RCD is faulty. Do not use the spa. 

  Contact a qualified electrician immediately to correct the fault.

WARNING

 

 

TEST

RESET

RESET

TEST

TEST

RESET

RESET

RESET

TEST

TEST

Summary of Contents for PureSpa PS-BH-10

Page 1: ...d boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates...

Page 2: ...ncy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a...

Page 3: ...ided for this purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not us...

Page 4: ...timers plug adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your ha...

Page 5: ...ge 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not...

Page 6: ...294 10 SPA DRAIN PLUG 1 11696B 11 SPA DRAIN VALVE ADAPTOR 1 11713 12 FILTER CARTRIDGE HOUSING 4 11798 13 FILTER CARTRIDGE 4 11692 14 FILTER CARTRIDGE HOUSING LID 4 11797 15 INLET OUTLET PLUG 6 11739 1...

Page 7: ...apacity 310 gal 1 173 L Inner outer size 152 3 86M 72 1 83M 50 1 27M 72 1 83M 52 1 32M 106 2 69M B A Height 28 in 71 cm Bubble air blower 1 1 HP 110 120 V 60 Hz Filter pump flow rate 323 gal hr 1 222...

Page 8: ...cilitate draining purposes during long term spa storage Make sure the floor is water resistant and non slip surface Do not install the spa on carpet or other materials that will be damaged by moisture...

Page 9: ...onal print copies Laminate the printed safety sign copy for protection from the elements Spa Control Unit Assembly 1 Connect the control panel 3 cable plug into the receptacle on top of the spa contro...

Page 10: ...it see drawing 7 3 Unscrew the air valve cap to reveal the stem in the up position for inflation Insert the other end of the inflation hose 7 into the valve and turn to the right to lock it in positio...

Page 11: ...it is firm to the touch but not hard see drawing 13 2 Disconnect the inflation hose 7 from the air blower inflation outlet and the valve 3 Replace the control base inflation cap 5 back close and rece...

Page 12: ...m the spa outlets before spa usage see drawing 17 Re attach them after usage for water filtration and cleaning 4 Before filling with water make sure the bottom drain valve caps are securely closed on...

Page 13: ...e following options are available During the heating process press the filter button for 3 seconds to switch the filtration function to the B side the heater will stop and the flame icon will turn off...

Page 14: ...ivated the filtration system will automatically start The filtration system can be activated together with the bubble function When the indicator light B is illuminated and the heater is off press the...

Page 15: ...at up the water to the desired temperature Press the temperature increase button to set the desired water temperature If problem persists contact Intex Service center E95 Water temperature too high Tu...

Page 16: ...g assembly back onto the spa tub wall 2 Change the spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections fo...

Page 17: ...ion of total alkalinity Result if too high Scale formation cloudy water shorter filter heater runs eye skin irritation poor chlorine efficiency Total Alkalinity TA indicates the degree of the water s...

Page 18: ...0 ppm you can add sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriati...

Page 19: ...ppm 350 ppm 250 ppm Desired level 100 ppm Water Volume Ratio Vhard water Vsoft water 1 9 1 4 2 5 2 3 Lowering Calcium Hardness Using Soft Water Raising pH Raising pH Using Sodium Bicarbonate Lowering...

Page 20: ...stops draining disconnect the spa control unit from the spa tub wall Lift the spa tub wall from the side opposite the drain leading any remaining water to the drain and emptying the spa completely se...

Page 21: ...he inside of the spa tub wall and turn the wrench 22 clockwise IMPORTANT Never adjust the air valve base when the spa is in use or filled with water Only use the air valve wrench if the air valve is l...

Page 22: ...nction is activated to avoid damage to the blower motor 4 Make sure all the spa components and accessories are thoroughly clean and dry before storage Air dry the spa tub in the sun for an hour before...

Page 23: ...vide a dedicated circuit breaker feeding the spa electrical outlet only Contact a qualify electrician to correct the electrical fault Increase the temperature and attach the spa cover Clean or replace...

Page 24: ...rmal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be s...

Reviews: