im_set_com_mode
4-45
4
im_set_com_mode
Purpose
This function specifies whether the communications port operates in RS-232
or RS-485 mode.
Syntax
#include "imt209x.h"
IM_STATUS im_set_com_mode
(
IM_USHORT mode) ;
IN Parameters
mode Identifies the communication mode. Choose one of these constants:
IM_MODE_RS232 RS-232 communication mode.
IM_MODE_RS485 RS-485 communication mode.
OUT Parameters
None.
Return Value
This function returns one of these codes:
IM_OK Success.
IM_INVALID_PORT The value for port_id is invalid.
IM_INVALID_MODE The value for mode is invalid.
See Also
im_set_port_direction