TRAKKER T2090 Hand-Held Batch Computer User’s Manual
6-22
End of Message (EOM)
Purpose:
Attaches an EOM to the end of a data block to indicate the end of data
transmission to and from a computer. When EOM is disabled, the computer
communicates in Character mode. When EOM is enabled, the computer
communicates in Frame mode.
You must configure a value for EOM before you can set these other serial
communications commands:
• Configuration Commands Via Serial Port
• Handshake
• LRC
•
Start of Message (SOM)
If EOM is disabled or not set, you need to disable these serial communications
commands.
EOM cannot equal the same value that is set for SOM. You cannot set EOM to
any of these values:
• AFF (ACK)
•
REQ (ENQ)
• DLE
•
SEL
• NEG (NAK)
•
XOFF
• Poll
•
XON
•
RES (EOT)
Syntax:
PFdata
Acceptable values for data are one or two ASCII characters.
Default:
\x03 (hexadecimal value for ETX)
Scan:
To disable EOM, scan this bar code:
Disable EOM
*$+PF*
*$+PF*
Or:
To set EOM to one or two ASCII characters:
1. Scan this bar code:
Enter Accumulate Mode / Set EOM
*+/$+PF*
*+/$+PF*
Summary of Contents for Trakker T2090
Page 1: ...TRAKKER T2090Batch Hand HeldComputer P N 067212 003 User s Manual ...
Page 4: ......
Page 14: ......
Page 19: ...Getting Started 1 ...
Page 20: ......
Page 33: ...User Interface 2 ...
Page 34: ......
Page 55: ...Application Development 3 ...
Page 56: ......
Page 61: ...Application Functions 4 ...
Page 62: ......
Page 127: ...Reader Command Reference 5 ...
Page 128: ......
Page 145: ...Configuration Command Reference 6 ...
Page 146: ......
Page 187: ...BIOS Support 7 ...
Page 188: ......
Page 205: ...Hardware Specifications 8 ...
Page 206: ......
Page 212: ......
Page 213: ...Demo Software A ...
Page 214: ......
Page 230: ......
Page 231: ...Microsoft Visual C C Settings B ...
Page 232: ......
Page 237: ...Full ASCII Charts C ...
Page 238: ......