TRAKKER T2090 Hand-Held Batch Computer User’s Manual
6-10
Codabar
Purpose:
Enables or disables decoding of Codabar symbology. Codabar is a self-checking,
discrete symbology. The American Blood Commission (ABC) Codabar requires
that you retain and transmit the start/stop code digits when processing a Codabar
symbol. Start/stop code digits are always transmitted.
Syntax:
CDdata
Acceptable values for data are one or two digits, corresponding to:
First digit
0
2
Disabled
Enabled
Second digit
0 or 1
Ignored
Default:
Disabled
Note:
The configuration CD20 is not permitted for consistency with other Intermec
products.
Scan:
One of these bar codes:
Disabled
Enable ABC, Transmit ABCD Start/Stop
*$+CD00*
*$+CD11*
*$+CD00*
*$+CD11*
Example
:
im_command (“$+CD11”,6);
will enable codabar.
Summary of Contents for Trakker T2090
Page 1: ...TRAKKER T2090Batch Hand HeldComputer P N 067212 003 User s Manual ...
Page 4: ......
Page 14: ......
Page 19: ...Getting Started 1 ...
Page 20: ......
Page 33: ...User Interface 2 ...
Page 34: ......
Page 55: ...Application Development 3 ...
Page 56: ......
Page 61: ...Application Functions 4 ...
Page 62: ......
Page 127: ...Reader Command Reference 5 ...
Page 128: ......
Page 145: ...Configuration Command Reference 6 ...
Page 146: ......
Page 187: ...BIOS Support 7 ...
Page 188: ......
Page 205: ...Hardware Specifications 8 ...
Page 206: ......
Page 212: ......
Page 213: ...Demo Software A ...
Page 214: ......
Page 230: ......
Page 231: ...Microsoft Visual C C Settings B ...
Page 232: ......
Page 237: ...Full ASCII Charts C ...
Page 238: ......