Chapter 2: Installation
14
TruVision PTZ 36X Camera User Manual
Figure 5: RS-485 setting
Half-duplex (Default)
(Switches 5 & 6 are unused)
Full-duplex
(Switches 5 & 6 are unused)
Setting the dome camera site ID
Before turning on the dome camera, you must set the dome camera site ID.
Each dome camera connected to the same network must have a unique ID. Use
the 10-bit DIP switch to set the dome camera’s site ID setting.
To set a dome camera site’s ID:
1. Locate the dome camera site ID DIP switch block (B, Figure 4 on page 10).
2. Using Table 5 below, determine which DIP switches need to be set to the on
position. The equivalent value of the switches will add up to create the site ID
number for that dome camera. See Figure 6 on page 16 for an example.
3. Place the switches that correspond to those values in the On position.
4. Carefully record the site ID of each dome camera installed.
Table 5: DIP switch positions and equivalent values
DIP switch position
number
1 2 3 4 5 6 7 8 9 10
Equivalent
value
1 2 4 8 16 32 64 128 256 512