background image

                                                           

 

A New User Friendly Concept GSM Alarm System for Your Assets! 

 

GSM Alarm System         

User Manual   

Ver 1.20    Date Issued: 2012-09-14 

 

Website: Http://www.alarmmate.co.za

 

Ver 1.00    Date Issued: 2012-09-01 

Summary of Contents for GSM Alarm System

Page 1: ...A New User Friendly Concept GSM Alarm System for Your Assets GSM Alarm System User Manual Ver 1 20 Date Issued 2012 09 14 Website Http www alarmmate co za Ver 1 00 Date Issued 2012 09 01 ...

Page 2: ...ction 2 2 Safety Directions 2 3 Standard Packing list 3 4 Physical Layout 3 5 Features 6 6 Settings 8 7 Operating Instructions 18 8 Installation 21 9 Add wireless sensors 26 10 Technical specifications 28 11 Important information 29 12 Maintenance 29 13 Quality Warranty 29 14 Trouble Shooting Guide 30 ...

Page 3: ...M card which supports the caller ID function 2 Safety Directions Safe Startup Do not use the GSM Alarm System while using other GSM equipment This could interfere with the set up of the alarm system Interference All wireless equipment might interfere network signals of GSM Alarm System and influence it s performance Avoid Use at Gas Station Do not use the GSM Alarm System at a gas station Power of...

Page 4: ...d Sensors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Magnetic Steel Scrolling Door Sensor Temperature Sensor Photoelectric Beams etc 4 Physical Layout 4 1 Control Unit physical layout Tips 1 In order to power off the alarm system press the switch inside for off and to the outside for on The power switch is equipped on the inside of the device it is nearby the SIM card socket Pleas...

Page 5: ...GSM ANT Connect the GSM ANT if the GSM signal is not strong then please change the 3dB GSM ANT Microphone One sensitive Microphone built inside Interface 2 Description 12V 12VDC 1A power output for wired detectors IN1 Digital input 1 connect to one wire of the wired Detector GND Ground point connect to another wire of the wired Detector or 12VDC IN2 Digital input 2 connect to one wire of the wired...

Page 6: ...red Detector 12V 12VDC 1A power output for wired detectors R1 Link Output Relay when the system alarm will close 4minutes Rated Voltage 3A 240VAC this relay can connect to any other lights or CCTV system as a switch R1 Built in 240VAC 3A rated relay output connect to the device s negative electrode R2 Independent Output Relay Can switch on or off by SMS Commands Rated Voltage 3A 240VAC this relay ...

Page 7: ...ed At house or Stay mode Disarmed and SOS are available 4 Armed delay alarm delay and other functions are programmable by the user 5 Watchdog 24Hours Zone and SOS zones are available 6 Uses an ICON to display Armed Partial Armed Disarmed Power status Siren status and GSM Signal status 7 Auto detects and reports GSM Signal Jammer alarm and SMS Switch is available 8 User friendly Icons for LED indic...

Page 8: ...or smoke and gas leakage sensor 1XWatchdog zone for monitoring elderly or children 1XSOS zone for emergency help 7 Supports 3 SMS alert numbers and 5 calling alert numbers and 100 alarm records for the owner s review 8 Supports Timer to automatically arm or disarm the system 9 Supports armed delay to give you enough time to go outside the home the delay time is editable by user 10 Equipped with 1 ...

Page 9: ...onnection status and display this on the LCD with 8 characters O stands for Open C stands for Close L stands for with 2 2K EOL E Stands for not includes the previous 3 states The device will register the GSM Network and display the GSM Signal ICON in the left corner of the LCD 4 All of the setup can be done by the LCD except to modify the Zone name if you need to modify the zone name please see th...

Page 10: ... want to test the two way voice communication please make sure the other phone is far from the device at least 500meters to avoid noise interference 9 Please setup at least one alarm alert number otherwise the mainframe will only activate the siren to work 6 times this is to remind you to setup alarm numbers 6 1 Key Function Descriptions 6 1 1 Led indicator Description The unit uses these icons to...

Page 11: ...to enter disarmed mode directly 6 1 3 Keyboard functions The unit uses these user friendly icons on the buttons Enter button dial out and answer incoming Hang up the incoming Exit and Backspace button Up button Down button Turn Left button in special menu need it to choose the option Disarm Button Arm Button At House Stay mode button Alarm link output indicator when alarmed will turn on and last 4...

Page 12: ...ecords 2 Timers 3 RF Zone Name 4 SMS Phone No 5 Auto dial No 6 Report Time 7 RF Code Query 8 Wired Zone Name 1 View 2 Setup To check the alarm records up to 100 event records will be saved To check the Timer you have setup To check the SMS Alert Contents of the Wireless Related Zones To check the SMS Alert Numbers To check the Auto dial telephone Numbers To check the report time To check the RF se...

Page 13: ...riggered will not alarm if the sensor hasn t been triggered it will alarm SOS Help In any mode the sensors with this type triggered will alarm but not drive the siren Alarm Action with Alarm occurrence the system will Automatically dial the Pre set 1 Edit RF Zone 2 Edit Remote Ctrl 3 Remove All 1 Add Del RF Parts 2 Wired Zones Set 3 Basic Setting 4 Advanced Setting To add or remove wireless sensor...

Page 14: ...VVV if the unit has been assigned You can press Enter to re assign new wireless sensors or remote controls to replace the existence ones 3 In the Edit RF Parts you can edit the attribute of the sensor as Normal or Stay type If the system is on Stay Mode Also At House or Partial Armed the sensor set as Normal triggered will not alarm the sensor set as Stay triggered will alarm If the system is unde...

Page 15: ...e Alarm 15 Watchdog alarm Watchdog Zone the attribute can not be modified In arm or disarm or stay mode once the sensor in this zone triggers in the preset time will not alarm if the sensor hasn t been triggered in the preset time will alarm 16 SOS Help SOS zone The attribute can not be modified In arm or disarm or stay mode once the sensor in these zones trigger will alarm immediately and not dri...

Page 16: ... wired zones each zone can be assigned one wired sensor and renamed by SMS Command 4 Wired Zone Serial Number Default Zone Name and Zone Attributes Table Zone SN Default Zone Name Default Zone Attribute 01 Outer Door Opened Normal 02 Intrusion from Left Fence Normal 03 Intrusion from Right Fence Normal 04 Intrusion from Front Fence Normal 05 Intrusion from Garden Fence Normal 06 24Hours zone alarm...

Page 17: ...retap the system site if somebody answers the call the two way voice communication will activate 1 SMS Phone No 2 Auto dial Tel No 3 Time Date 4 Sound Alarm 5 Report Time Gap 6 Power Failure Alert 7 Arm Delay Time 8 Alarm delay Time To setup the SMS Alert Number must be cell phone numbers total 3 To setup the Auto dial telephone number total is 5 numbers To setup the time and date information The ...

Page 18: ...ower failed for 30minutes if the power is recovered it will send an SMS AC Power is OK Default is then disabled 6 There s no delay for Stay Mode 6 2 2 4 Advanced Setting For example In South Africa the country code is 0027 please note do not write 27 The user cell phone number is for example 082 123 4567 and has been assigned as a SMS Alert number the SIM Card number in the panel is for example 08...

Page 19: ... 90seconds the system will drive the siren for 60seconds and the link output relay will close for 4 minutes 6 3 Modify the SMS Alert Content of the Zone Zone or Sensor Name The unit accepts SMS Command to modify the SMS Alert Content of the zone For Wireless Zone Name the format is Password M Zone Serial Number New Zone Name Characters for the zone name are 32 The Zone Serial Number is 01 16 corre...

Page 20: ...Modify the first wired zone name as Front Door Opened by Intruder You should edit a SMS Content 1234 Z01 Front Door Opened by Intruder the 1234 is the password Then send it to the SIM card Number 7 Operating Instructions Tips The user can arm disarm Stay Partial armed by Remote controls Keyboard or SMS The user can cancel the alarm by Remote Controls Keyboard or SMS to disarm The user can switch t...

Page 21: ...ered will alarm The sensors which had been set as normal Type triggered will not alarm Please see the menu of the Edit RF Zone Press Emergency button SOS on the remote control or the control unit or Press any Emergency button The Control Unit will enter emergency alarm The siren will not sound but will alert the pre set phone number immediately 7 2 SMS Commands for Arm or Disarm or Inquiry system ...

Page 22: ...s Return SMS Armed or At House or Disarmed AC Power is Ok or AC Power is failed GSM Value is 17 or other value Output Relay is Closed or Output Relay is opened Example 1111DD When the Password is 1111 xxxxDD xxxx stands for the password 1 4 digits Return SMS Output Relay Opened Example 1111CC When the Password is 1111 xxxxCC xxxx stands for the password 1 4 digits Return SMS Output Relay Closed Ex...

Page 23: ...ces are more than 3 5m from the mainframe 8 1 Insert SIM into Control Unit and install the GSM ANT In the backside of the control unit please install the GSM SIM card The GSM ANT must be installed vertical to ensure good working condition 8 2 Install the Wireless Magnetic door window sensors Magnetic door window sensors signal the Control Unit when the two parts separate by more than 1 5 to 3 0cm ...

Page 24: ... steel door Installation attach the larger half to the floor and attach rivet or glue the smaller half to the scroll steel door An alarm is triggered when the halves are separated by more than 3 to 5 00 cm Scroll Steel Door 8 3 Install the wireless PIR Motion Sensor The PIR sensor will detect a person since human temperature is different to ambient temperature When triggered the PIR will signal th...

Page 25: ...wiring diagram then fix the related wired sensors and the sensors connected to the related digital inputs Tips 1 Please setup the NC NO EOL type in the PC Programmer correctly 2 If you setup the Nodes type as NC Default the no use inputs must be short circuited by wires and the sensor type must be NC Please see below diagram 3 If you setup the input type as EOL then please contact a 2 2K resistor ...

Page 26: ...ord is rated while you connect to equipment device Please make sure the power consumption is less than 250W If you need heavy equipment please connect an additional relay 6 The R1 and R1 is for alarm link output when the system alarms it will close for 4 minutes the rated output power is 700W If you need heavily equipment please connect an additional relay 7 The R2 and R2 is the relay output for S...

Page 27: ...operator If applicable ensure that an uninterruptible AC power outlet is available near the Control Unit First connect accessories to the Control Unit then the AC adapter 8 6 Install Siren Connecting the Siren to the Control Unit and fix them in appropriate locations Tips The Siren should be at least 1 5meters away from the GSM SMS Controller unit if possible more than 3meters 9 Add Wireless Senso...

Page 28: ...f you need to add more then you can set the wireless sensor with the same jumper Add additional wireless sensors to the control units please see below 9 1 Prepare the RF Sensors of PT2262 IC Code 1 Prepare the RF sensors Open the back cover of the Wireless sensor carefully 2 Locate the IC boards black jumpers labeled A0 A7 and D0 D3 3 Configure the A0 A7 and D0 D3 different from each wireless sens...

Page 29: ...ols use learning codes you can add the remote control to the unit directly following the 6 2 2 1 Add Del RF parts a Enter the Add Del RF Parts menu b Select 2 Edit Remote Ctrl then press Enter button c Follow the instruction 1 Turn On the Device this means trigger the Remote Control the system will show a code then press Enter Key on the keyboard The system will ask you repeat the operation so ple...

Page 30: ...ndition Size 180mmX125mmX30mm LXWXH Net Weight 0 36Kg 11 Important information 1 The Control unit will auto switch off when the backup battery voltage is less than 3 7V Before switching off it will drive the buzzer to alert you by sounds 2 Please read the User Manual carefully before you install and set the Control Unit 3 The siren and relays will not work if the AC DC power goes off because both ...

Page 31: ...ty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions 15 Trouble Shooting Guide PROBLEM CAUSE POSSIBLE SOLUTION GSM Module initialization failed 1 Backup battery with low voltage GSM Module connection loose in transportation 2 GSM Signal is too weak 1 Please contact the AC Power 2 Please take the panel to a mobile phone repairmen store ask ...

Page 32: ... 1 Please see the PIR Motion sensor installation user manual carefully 2 Please check if any sensor assigned to these special zones are incorrectly activated 3 Please check the detector NC NO type and NC NO EOL are correct and a 2 2K resistor is in the un use input ports Alarm without SMS Alarm without Dial No action after send SMS command 1 GSM Operator communication protocol 2 Haven t setup SMS ...

Reviews: