JA-63 “Profi“ User manual  

 

 

 

Internet: www.jablotron.cz

Tel.: +420 483 559 999  

fax: +420 483 559 993

Pod Skalkou 33 

466 01 Jablonec nad Nisou

Czech Republic 

 

 

Summary of Contents for JA-63 PROFI"

Page 1: ...JA 63 Profi User manual Pod Skalkou 33...

Page 2: ...2 11 Appliance control 8 3 User s settings 8 3 1 New master code 8 3 2 User codes setting 9 3 3 Internal clock setting 9 3 4 Automatic arming disarming 10 3 5 Bypass 10 4 Telephone communicator progra...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...11 press the A button system will beep once and the exit delay countdown will start B A ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exi...

Page 6: ...depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the JA 60D keypad enter F7 On the remote control RC 11 press the A an...

Page 7: ...stem history can be viewed using a PC with Comlink software Alarms and failures can also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times...

Page 8: ...ntrol an electrical appliance light heating ventilation etc In such a case users can operate the device Locally with keypad entering F81 ON or F80 OFF The JA 60D keypad does not support this feature R...

Page 9: ...the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in a safe place The JA 60D keypad has its own access codes which can be...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...mmunicator and if the installer enabled the supervisor to modify the communications settings only then will the following programming be possible 4 1 Telephone communicator testing Testing is possible...

Page 12: ...user mode To switch the control panel to the user mode enter F 0 master code User mode will be indicated by a U on the keypad If Jablotron s SMS server service is provided in your country check with...

Page 13: ...8 Pager dialing can be deleted with 7 F0 F5 To exit user mode press N 5 System testing The supervisor should test the system monthly For testing the control panel should be in the user mode Enter F0 m...

Page 14: ...l battery capacity can shorten the battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be...

Page 15: ...Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 SMS message o Pager Timers exit entrance del...

Page 16: ...location in the house detectors type reaction A B S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WIRELESS DETECTORS 16 1 2 3 WIRED INPUTS 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...