Chapter 1: Product introduction
4
TruVision PTZ 36X Camera User Manual
Power cable size and length requirements
Using the proper gauge of power cable will ensure proper operation and
avoid voltage drops. See Table 2 below for the recommended cable gauge
for varying maximum cable lengths and power draws.
Table 2: Recommended power cable gauges based on maximum lengths for an
operating voltage of 24 VAC (±10%)
Wire gauge
Indoor dome cameras
(14 W)
Outdoor dome cameras
(54 W)
AWG
mm
(diameter)
feet meters feet meters
10 2.59 2061 628 534 163
12 2.05 1294 394 335 102
14 1.63 813 247 211 64
16 1.29 512 156 133 41
18
1.02 322 98 83 25
20
0.81 203 62 53 16
22
0.64 127 39 33 10