NS3503-16P-4C User Manual
302
4.15.6 PoE Alive Check Configuration
The NS3503 Ultra PoE Switch can be configured to monitor connected PD’s status in real-time via ping
action. Once the PD stops working and without response, the PoE Switch is going to restart PoE port
power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator
management burden.
This page provides you with how to configure PD Alive Check. The screen in Figure 4-16-6 appears.
Figure 4-15-6: PD Alive Check Configuration Screenshot
The page includes the following fields:
Object
Description
Mode
Allows user to enable or disable per port PD Alive Check function.
By default, all ports are disabled.
Ping PD IP Address
This column allows user to set PoE device IP address for system making ping
to the PoE device. Please note that the PD’s IP address must be set to the
same network segment with the PoE Switch.