Appendix B: Reference Tables
Activity Levels as Follows:
\
96
Fire Supervisory
A fire supervisory trouble has
been detected.
§
1, 2, 3, 4,
5
Aux./Aux.
Instant
√
√
Note: Check marks (
√
) represent characteristics present in a type.
*
This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
†
Sounds instant police siren if two or more sensors are tripped within 4 minutes; otherwise sensors are followers to delayed
sensors. If central station Alarm Verification feature is on, type 18 functions like type 17.
‡
This type has not been investigated by UL.
§ Zone trip causes trouble, restoral causes trouble restoral.
Table B1: Zone Type Characteristics (Continued)
No.
Name
Application
A
c
tiv
e
L
eve
l
Ala
rm
/Sire
n
De
la
y
Supe
rviso
ry
R
e
stor
al
CS Ala
rm
Re
p
o
rt
CS Ca
nc
e
l Re
port
B
y
p
a
ss
ab
le
Chim
e
R
e
se
ts
A
c
tivity
T
imer
Level #
Name
Description
Attributes
Level 1
OFF
The partition/area is disarmed. Only 24-hour sensors cause an alarm in the
OFF level. Cancelling alarms or entry delay automatically disarms to OFF.
- Open
- Entry, but no exit delay
- Cannot be disabled
Level 2
PERIMETER/
HOME
The user is on-site and only requires perimeter protection. In addition to 24-
hour sensors, perimeter sensors such as those protecting exterior doors and
windows cause an alarm in the HOME/PERIMETER level.
- Closed
- Entry and exit delay
- Can be disabled
Level 3
FULL/AWAY
The user is away and requires complete protection. 24-hour sensors, perimeter
sensors, and interior sensors cause an alarm in the AWAY/FULL level.
Same as Level 2.
Level 4
NIGHT
The user is on-site and perimeter and 24-hour sensors are active. Since users
are not moving around, Interior sensors except those in night groups are also
active.
Same as Level 2.
Level 5
SILENT
Same as Level 3, but police intrusion alarms are silent.
Same as Level 2.