14
Commercial Burglary and Home Navigator System
Powering Up the Panel
Figure 23. Wiring an AC Power Transformer to the
Panel
Installing Panel Backup Battery(s)
The panel uses from one to three rechargeable, sealed 12V
lead-acid backup batteries (60-781).
Note
When replacing batteries, always replace with the same
battery type and size.
To install (or replace) backup battery(s):
1. Make sure the panel AC power is off or disconnected.
&$87,21
While AC power is applied to the panel, the charging
voltage is present at the battery leads.
2. Verify all wiring at the panel and devices for correct ter-
minations.
3. Place the battery in the lower left or right portion of the
panel enclosure, with the terminals facing up.
4. Connect the black battery wire(s) from the panel circuit
board negative (-) battery spade lug(s) (located on the
left side of the board) to the negative (-) battery terminal
(Figure 24).
5. Connect the red battery wire(s) from the panel circuit
board positive (+) battery spade lug(s) to the positive (+)
battery terminal.
6. On three battery installations, wire the third battery in
parallel (positive to positive and negative to negative)
with either of the two sets of battery spade lugs on the
panel.
:$51,1*
!
Never short-circuit or reverse the battery wires. Possible
injury to you and/or permanent damage to the panel and
battery could result.
Figure 24. Connecting Backup Battery(s)
Powering Up the Panel
After connecting and wiring all devices to the panel, you are
ready to power up the panel.
To power up the panel:
1. If you have not already done so, connect the backup bat-
tery(s).
2. Depending on your transformer,
q
Plug the transformer into an outlet not controlled by
a switch,
q
or apply power to the circuit which the transformer is
connected to.
3. Wait about 30 seconds and note the following:
q
The green power LED (located on the circuit board)
turns on and stays on.
q
Alphanumeric touchpads should display “
PARTITION
1
SECURITY
IS
OFF
.”
Note
If the power LED is off or flashing, or if touchpads don’t
display anything, remove panel power, disconnect the
backup battery(s) and see “Troubleshooting” on
page 48.
Programming the Panel
The panel can be programmed using downloader software
or an alphanumeric touchpad connected to the panel. The
system interface is menu-driven and self-prompting. It will
automatically request access codes and data if required.
1
2
24
VAC
24
VAC
TO 110 VAC 60 HZ
CIRCUIT
SPLICE
TO 110 VAC 60 HZ
OUTLET
LINE
LOAD
CLASS 1
24 VAC 100 VA
60-830
LOAD
CLASS 2
24 VAC 100 VA
60-823
OR
LINE
BUILT-IN
CIRCUIT
BREAKERS
PANEL TERMINALS
8543269A.DSF
1
2
24
VAC
24
VAC
O R
B L K
R E D
S I N G L E B A T T E R Y C O N N E C T I O N S ( S T A N D A R D )
1 2 V
B A C K U P
B A T T E R Y
+
+
R E D
B L A C K
6 0 - 7 8 1
P A N E L
B A C K U P
B A T T E R Y
L U G S
+
4 9 - 4 8 4
4 9 - 4 7 6
T R I P L E B A T T E R Y C O N N E C T I O N S ( O P T I O N A L , N O T S H O W N )
W I R E T H I R D B A T T E R Y I N P A R A L L E L W I T H A N Y O T H E R
B A T T E R Y U S I N G A D D I T I O N A L 4 9 - 4 7 6 A N D 4 9 - 4 7 6
B A T T E R Y C A B L E S .
D U A L B A T T E R Y C O N N E C T I O N S ( O P T I O N A L )
P A N E L
B A C K U P
B A T T E R Y
L U G S
+
R E D
B L A C K
1 2 V
B A C K U P
B A T T E R Y
+
1 2 V
B A C K U P
B A T T E R Y
+
6 0 - 7 8 1
B L K
R E D
+
B L A C K
R E D
6 0 - 7 8 1
B L A C K
R E D
4 9 - 4 8 4
4 9 - 4 7 6
4 9 - 4 8 4
4 9 - 4 7 6
8 5 4 3 2 7 9 B . D S F
Summary of Contents for Advent