Use Table A1 to determine maximum and standby current
draw based on the devices connected to the panel.
Customer Name _________________________________
Address _______________________________________
City _________________ County ___________ State ___
Zip __________ Phone (____) _______________
Table A1: System Hardwire Devices
Part No.
Description
Qty.
Standby Current Draw
Standby
Current
Subtotal
Maximum
Current Draw
Maximum
Current
Subtotal
Hardwire Sensors/Detectors
13-082
PIR Motion Detector
10 mA
10 mA
13-443
2-Wire Smoke Sensor
100 uA
N/A
13-444
2-Wire Smoke/Heat Sensor
100 uA
N/A
Fire Pull Station
N/A
N/A
Hardwire Sirens/Speakers
13-046
Hardwire Exterior Siren
N/A
145 mA
13-060
8 Ohm, 15W Speaker
N/A
N/A
SuperBus 2000 Touchpads and Modules (31 Devices per Bus Header)
60-768
SuperBus 2000 Dual Phone
Line Module
20 mA
60 mA
60-783
(plastic)
60-854
(metal)
SuperBus 2000 Printer Module
30 mA
35 mA
60-783-02
SuperBus 2000 RS 232 Auto-
mation Module
*
35 mA
35 mA
60-803-01
SuperBus 2000 2x20 LCD
Alphanumeric Touchpad
75 mA
120 mA
60-804-01
SuperBus 2000 2x20 VFD
Alphanumeric Touchpad
75 mA
120 mA
60-810-04
SuperBus 2000 2x20 VFD Fire
Alphanumeric Touchpad
75 mA
120 mA
60-821-95
(plastic)
60-856-95
(metal)
SuperBus 2000 RF Commer-
cial Transceiver Module
50 mA
50 mA
60-774
SuperBus 2000 8Z Hardwire
Input Module
18 mA
35 mA
60-770
SuperBus 2000 4-Relay Out-
put Module
25 mA
180 mA
SnapCards (2 per panel)
60-756
4 Input/2 Output SnapCard
10 mA
+ 2.5 mA per zone used
+ 7 mA per smoke loop used
+ 34 mA per relay used
185 mA
60-757
8Z Hardwire Input SnapCard
10 mA
+ 2.5 mA per zone used
+ 7 mA per smoke loop used
230 mA
60-758
4 Output SnapCard
6 mA
+ 34 mA per relay used
130 mA
Total Standby Current Draw (must not exceed 150 mA with 1 battery, 850 mA with 2 batteries, or 1.5A with 3 batteries for UL systems).
Total Maximum Current Draw (must not exceed 5A).
* Not investigated by UL.