![Interlogix Advent Installation Instructions Manual Download Page 3](http://html.mh-extra.com/html/interlogix/advent/advent_installation-instructions-manual_2077278003.webp)
1
Commercial Burglary and Home Navigator System
About This Manual
About This Manual
This manual provides information for planning, installing,
programming, and testing an Advent Commercial security
or Home Navigator system. When necessary, this manual
refers you to other documentation included with compatible
peripherals.
“Appendix A: System Configuration Worksheets” on
page 58 are included for you to record hardware layout and
software programming settings.
About the User Guide
The User Guide contains user worksheets that should be
filled out during the installation and programming of the
system.
Special Installation Requirements
Commercial Burglary Panel
The commercial burglary panel can be used as an intrusion
alarm system. Follow the installation guidelines below:
q
Some installations may require configurations dictated
by city/state codes, insurance, or Underwriter’s
Laboratories (UL). See the following section “UL
Listed Installations” for various UL component and con-
figuration listings.
UL Listed Installations
This section describes the minimum requirements for differ-
ent UL Listed installations.
Basic System
q
Commercial Burglary (60-562-01, 60-562-04) or Home
Navigator (60-562-02, 60-562-05) Control Panel
q
SuperBus 2000 VFD (60-804-01) or LCD (60-803-01)
Alphanumeric Touchpad
q
24 VAC output, 100 VA Class I, 110VAC, 60 Hz
(60-830) or 24 VAC output, 100 VA Class II, 110VAC,
60 Hz (60-823) Line Carrier AC Power Transformer
q
17.2 AH or 18.0 AH Backup Battery(s) (60-781)
q
Backup Battery Cable Assemblies (49-484 [red] and 49-
476 [black])
q
UL listed 4 ohm, 15W Speaker
q
2K ohm EOL Resistor(s) (49-467)
Police Station Connected Burglary Alarm Units and
Systems (UL 365)
Basic system using Commercial Burg control panel
(60-562-01 or 60-562-04).
The basic system may also include:
q
Hardwire Magnetic Contact (13-068 or 13-071) or
Wireless Learn Mode Door/Window Sensor (60-362).
q
A SuperBus 2000 Commercial RF Transceiver
(60-821) for use with listed wireless signaling devices.
q
A SuperBus 2000 Printer or Automation Module
(60-783) for use with a listed printer.
q
A SuperBus 2000 Dual Phone Line Module (60-768) for
expansion to primary and secondary phone line reporting.
System Setup and Programming
The system Feature Numbers shall be set as follows in UL
365 listed systems:
Local Burglar Alarm Units and Systems (UL 609)
Basic system using Commercial Burg control panel
(60-562-01 or 60-562-04), plus:
q
Hardwire Magnetic Contact (13-068 or 13-071) or
Wireless Learn Mode Door/Window Sensor (60-362).
The basic system may also include:
q
A SuperBus 2000 Commercial RF Transceiver
(60-821) for use with listed wireless signaling devices.
q
A SuperBus 2000 Printer or Automation Module
(60-783) for use with a listed printer.
Table 1: UL 365 Listed System Settings
Feature No.
Feature
Required Setting
xx002
Siren Sound Time
16 min. minimum
xx003
Entry Delay
45 sec. maximum
xx004
Exit Delay
60 sec. maximum
yy003
Number of Attempts
5 min. 10 maximum
yy004
Communication Format
0 Contact ID
xx088
Report Partition/Area Events
1-On
xx092
Auto Forced Arming
0-Off
xx097
Exterior Siren Arming Verifi-
cation
0-Off
xx098
Local Closing Report Verifica-
tion
1-On
xx102
Exit Delay Reset
0-Off
xx108
Local Trouble Annunciation at
LTIME
1-On
17034
Auto Phone Test Frequency
1 Day
17036
AC Stable Time
90 sec. maximum
17041
AC Report Delay
6-12 hours
17049
Supervisory Time A
4 hours
17069
Phone Trouble Disable
0-Off
17072
RF Jam Detect Sound Enable
1-On
17073
Automatic Panel Backup Bat-
tery Test Interval
1=4 hours
17076
Commercial/Residential
1-Commercial
17078
Detect RF Receiver Failure
1-On
17079
Alarm Messages Played at
High Volume
1-On (High)
17096
Report System Events
1-On
47004
#2 Supervisory Time Zone
Attribute (all zones)
#4 Hardwire Smoke Verify
Zone Attribute
Set to 4 hours
0-Off
xx = Two digit partition number.
yy = Two digit non-pager phone number.
Summary of Contents for Advent