Server System R2000WT Product Family System Integration and Service Guide
44
2.8.4
PCI Riser Assembly Installation
Figure 56. Installing PCI Riser Assembly
Note
:
Steps 1, 2, 5, 6, and 7
are only needed when a full-length PCI card is installed on the riser assembly.
•
Slide back the blue card guide on the air duct (see letter ‘A’)
•
If installed, remove the blue plastic pin from the card guide (see letter ‘B’)
•
Position the riser card’s edge connector over the riser slot on the server board and align the two hooks
on the back edge of the riser assembly with the slots on the back of the chassis
•
Once aligned, press the riser assembly straight down into the riser slot (see letter ‘C’)
NOTE
: Do NOT rock
the riser assembly into place; doing so may damage the contact pins within the riser slot
•
Slide forward the card guide to lock in the back edge of the full–length add-in card (see letter ‘D’)
•
Locate the blue plastic pin to secure the back edge of the full-length add-in card to the card guide
•
Insert the blue plastic pin into the card guide and through the matching hole in the add-in card (see letter
‘E’)
•
Connect any cables to the add-in cards that require them. See your add-in card documentation for
additional information