Server System R2000WT Product Family System Integration and Service Guide
123
Table 11. Integrated BMC Beep Codes
Code
Associated Sensors
Reason for Beep
1-5-2-1
No CPUs installed or first CPU socket is
empty.
CPU1 socket is empty, or sockets are populated
incorrectly
CPU1 must be populated before CPU2.
1-5-2-4
MSID Mismatch
MSID mismatch occurs if a processor is installed
into a system board that has incompatible power
capabilities.
1-5-4-2
Power fault
DC power unexpectedly lost (power good dropout)
– Power unit sensors report power unit failure
offset
1-5-4-4
Power control fault (power good assertion
timeout).
Power good assertion timeout – Power unit
sensors report soft power control failure offset
1-5-1-2
VR Watchdog Timer sensor assertion
VR controller DC power on sequence was not
completed in time.
1-5-1-4
Power Supply Status
The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is
present that is an incompatible model with one or
more other PSUs in the system.