Intel
®
Server Board S5500BC TPS
Appendix B: Sensor Tables
Revision 1.0
Intel order number: E42249-003
93
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Processor 2 Thermal
Margin
(
P2 Therm Margin
)
63h
Dual
processor
only
Temperature
01h
Threshold
01h
– –
–
Analog
–
–
–
Processor 1 Thermal
Control %
(
P1 Therm Ctrl %
)
64h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
Trig
Offset
A –
Processor 2 Thermal
Control %
(
P2 Therm Ctrl %
)
65h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
Trig
Offset
A –
Processor 1 VRD Temp
(
P1 VRD Hot
)
66h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig
Offset
M –
Processor 2 VRD Temp
(
P2 VRD Hot
)
67h
Dual
processor
only
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig
Offset
M –
Catastrophic Error
(CATERR)
68h All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Non-fatal
As and
De
–
Trig
Offset
M –
CPU Missing
(CPU Missing)
69h All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
–
Trig
Offset
M –
IOH Thermal Trip
(IOH Thermal Trip)
6Ah All
Temperature
01h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
–
Trig
Offset
M –