Intel® Server D50TNP Family Integration and Service Guide
149
Figure 211. Add-in Card Installation
3.
If installed, carefully remove the original rear metal filler plate from the metal frame of the riser assembly
(see Letter A).
4.
Align the rear bracket of the add-in card to the rear opening of the riser assembly.
5.
Carefully push the add-in card down into the PCIe* slot (see Letter B).
6.
Ensure the add-in card is fully seated.
7.
Reinstall the riser card assembly into the module (see
Section 7.8.3
).
7.8.3
Riser Assembly Installation
Figure 212. Installing a Riser Assembly
1.
Align the riser card edge connector to the riser slot on the server board (see Letter A).
2.
Carefully push down on the riser assembly until the riser card is securely seated into the riser slot.
3.
Ensure the three screw holes of the riser assembly are aligned and flush with the mounting holes of the
module.
4.
With three screws, secure the riser assembly to the module using 8 lbs. of torque on each screw
(see Letter B).
1U air-cooled module shown
1U air-cooled module shown