126
5.
In the tree on the right side of the tab, select from the following condi-
tions and actions that can trigger the alarm output:
•
Alarm Activation.
Select the alarm inputs for DVXNotify to monitor
for activation. If the Minimum Latch Time equals zero, the alarm out-
put is triggered until the alarm input is deactivated.
•
Video Signal Loss.
Select the camera inputs for DVXNotify to moni-
tor for video signal loss. If the Minimum Latch Time equals zero, the
alarm output is triggered until the video is restored to the camera
input.
•
Video Scene Loss.
Select the camera inputs for DVXNotify to moni-
tor for scene loss, which means that the video signal is still present,
but the camera sees only one consistent color (if it is covered or the
lens is painted black, for example). If the Minimum Latch Time equals
zero, the alarm output is triggered until the camera is returned to
normal operation.
•
Other Events.
Select whether you want DVXNotify to monitor the
termination of recording (either Recording Stop or Recording Hard
Stop). If the Minimum Latch Time equals zero, the termination of re-
cording triggers the alarm output until recording is restarted.
6.
Select Done when the output alarm settings are configured as desired.