The DVXMonitor tab contains the following options (see Figure 57):
•
Disable DVXMonitor—
disables DVXMonitor’s ability to watch for fail-
ure conditions.
•
Time Before Reboot (Minutes)—
the amount of time between the occur-
rence of a restart situation (such as MasterControl failure) and the sys-
tem restarting.
•
Minimum Latch Time (Seconds)—
the minimum amount of time that the
alarm output is triggered when a selected event occurs. The alarm is trig-
gered for a longer amount of time only if the alarm event duration ex-
ceeds the minimum latch time.
•
Reset Alarm Output—
forces the trigger to its normal state (closed). This
overrides the Minimum Latch Time.
•
Latch Until Forced—
causes the alarm output to remain activated when a
selected event occurs, until Reset Alarm Output is selected.
•
Alarm Scheduling—
a schedule of when the DVX 1000 system is moni-
tored for failure by DVXMonitor.
Figure 57
The DVXMonitor
plug-in allows you
to configure DVX
1000 to trigger the
alarm output when
certain conditions
or actions occur.