THE FORCE/2
Troubleshooting Cont.
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
Blower does not
Loose wire in electrical
Have the system inspected
operate or variable
system.
and repaired by a
speed does operate.
qualified service center.
Worn brushes in blower motor Have the brushes inspected
and replaced by a
qualified service center.
Inline fuse blown.
Turn machine upside
down. Locate fuse holder
on electrical box. Remove
blown fuse and replace
with 15 amp AG style fuse.
Agitator trips circuit
Low voltage 99-104v.
FORCE/2 requires a
breaker at main
minimum of 20 amps
panel.
@ 115V. Relocate power
cord to a dedicated 20
amp circuit.
Incorrect size extension cord. For an additional 50' run,
use 10/3 cord. For a 100'
run use 8/3 cord.
Pushing down on material
Do not push down on
in hopper.
insulation while filling hopper.
Wet insulation material in
Do not use wet
hopper.
material. Disconnect
electrical power and
remove wet material.
Worn or frozen airlock
Have bearing checked and
bearing.
replaced by a qualified
technician.
Blower trips circuit
Low voltage.
Blower requires a minimum
breaker at power
of 20 amps @ 115V. Use a
source.
dedicated refrigerator outlet
or equivalent.
Incorrect extension cord.
For an additional 50'
run, use 10/3 cord. For
a 100' run use 8/3 cord.
Operator in attic
Static electricity from
Mix half-and-half solution
keeps getting
insulation.
of water and fabric softener.
shocked.
Mist into insulation while
loading hopper.
Note:
Excess moisture will cause
jamming.
Problem
Likely Cause
Remedy
28
Summary of Contents for FORCE/2 HP
Page 2: ......
Page 4: ...MACHINE INFORMATION 2 ...
Page 46: ...ELECTRICAL DRAWINGS 44 Wiring Diagram Manufactured from 8 02 Present Electrical with GFCI ...
Page 49: ...ELECTRICAL DRAWINGS 47 Wiring Diagram Mfg from 9 02 Present Electrical With Remote Disconnect ...
Page 50: ......
Page 52: ...ELECTRICAL DRAWINGS FORCE 2 Electrical Drawings Cont d ...