THE FORCE/2
Troubleshooting Cont.
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
Problem
Likely Cause
Remedy
27
Machine does not run Main panel circuit
Wait for a few minutes,
Cont.
breaker tripped.
push to reset.
Air, but no material,
Slide gate closed.
Open to operating
comes out of hose
position.
Bridging (air pocket
Turn machine “off” and
in hopper).
disconnect from electrical
power. Redistribute material
in hopper. Reconnect to
electrical power.
Remote rocker switch for
Replace with original
agitator motor has failed.
factory part.
Circuit breaker tripped
Push to reset.
on main panel.
Jam between blade of
Disconnect electrical power.
agitator and airlock.
Remove insulation material
from hopper. Locate jam and
remove material with pliers.
Blower power cord is not
Check connection on power
plugged in at main panel
cord at main panel or
or power cord does not
make sure electricity is
have electrical power at
present at power
source.
source.
Start up capacitor blown
Have capacitor replaced by
on agitator motor.
a qualified service center.
Blower does not
Variable speed bypass
Position the variable speed
operate or variable
switch is in the neutral
bypass toggle switch to either
speed does operate.
position.
the “on” or “o position. If
the switch is located in
between the on/off text, it is
in the neutral position and the
blower will not operate.
Blower rocker switch on
Switch rocker to “on”,use
main panel is “off”.
remote box to operate.
Remote rocker switch for
Replace with original
blower motor has failed.
factory part.
Loose power cord/extension Check condition of
cord at electrical system.
electrical plug blades.
Summary of Contents for FORCE/2 HP
Page 2: ......
Page 4: ...MACHINE INFORMATION 2 ...
Page 46: ...ELECTRICAL DRAWINGS 44 Wiring Diagram Manufactured from 8 02 Present Electrical with GFCI ...
Page 49: ...ELECTRICAL DRAWINGS 47 Wiring Diagram Mfg from 9 02 Present Electrical With Remote Disconnect ...
Page 50: ......
Page 52: ...ELECTRICAL DRAWINGS FORCE 2 Electrical Drawings Cont d ...