THE FORCE/2
Maintenance, Cont.
M
A
I
N
T
E
N
A
N
C
E
Recommended gearbox oil:
Model 22014
Capacity: 48 oz.
Temperature 40˚ - 100˚ F Mobil SHC 634 gear lube
Temperatures -20˚ - +40˚ F Mobil 1 synthetic 5W-30
Gearbox/Agitator/Airlock Unjamming procedure:
Empty hoper,
disconnect all electrical cords to machine. Tip machine upside down onto hopper.
Remove agitator motor cover on outside of machine (black plastic). Locate and
remove fan cover on agitator motor. Note: Depending upon the motor used it will
be necessary to remove the screws holding the fan cover on before removal,
otherwise all other covers may be pried off using screwdriver. By hand, carefully turn
fan blade counter-clockwise until jam is cleared. Note: It will take approximately 15
turns of the fan blade before you start to reverse the entire airlock system. Caution!
Fan blade may break if excessive force is used.
Note:
The gearbox and the airlock must be perpendicular to each other. Proper
alignment prevents premature wear on the gearbox and airlock shaft connection.
Drain & Fill plug
Model 22014
Vent Plug
1
⁄
4
-
1
⁄
2
Turn to Vent
22
Removing Cover
Rotation Label
Turn by hand
Using Screw Driver
Summary of Contents for FORCE/2 HP
Page 2: ......
Page 4: ...MACHINE INFORMATION 2 ...
Page 46: ...ELECTRICAL DRAWINGS 44 Wiring Diagram Manufactured from 8 02 Present Electrical with GFCI ...
Page 49: ...ELECTRICAL DRAWINGS 47 Wiring Diagram Mfg from 9 02 Present Electrical With Remote Disconnect ...
Page 50: ......
Page 52: ...ELECTRICAL DRAWINGS FORCE 2 Electrical Drawings Cont d ...