THE FORCE/2
Troubleshooting, Cont.
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
Machine makes a
Gearbox drive not
Loosen gearbox and
grinding noise when
engaged with airlock
gearbox stabilizers. Align
running.
rotor connection out
gearbox and airlock shaft
of alignment.
perpendicular to each other.
Resecure bolts. Replace
gearbox stabilizers if bent.
Low oil level in gearbox.
Have the gearbox
inspected and repaired by a
qualified service center. See
gearbox section for oil capacity.
Agitator fan cover rubbing
Remove black plastic cover
against rotating fan blade.
on outside of machine.
Remove agitator motor fan
cover and inspect fan blade
and bend cover back to
normal condition.
Decreased material
Worn airlock seals.
Inspect seals for tears or
throw.
cuts. See maintenance
section to replace or adjust
as necessary.
Kink in hose.
Run hose as straight as
possible to help maintain
production.
Excess air leaking into
Inspect seals for tears or
hopper.
cuts. See maintenance
section to replace or adjust
as necessary.
Material buildup in
Turn machine upside down
blower housing.
and use compressed air to
blow out air intake. See
diagram.
Machine does not run Remote cord not plugged
Plug in remote cord into
into electrical panel
electrical panel and position
the agitator and blower switch
to the on position.
Blower power cord is not
Check connection on power
plugged in at main panel
cord at main panel or
or power cord does not
make sure electricity is
have electrical power at
present at power source.
source.
No power.
Check source of electrical
power. Possible tripped
circuit breaker.
Problem
Likely Cause
Remedy
26
Summary of Contents for FORCE/2 HP
Page 2: ......
Page 4: ...MACHINE INFORMATION 2 ...
Page 46: ...ELECTRICAL DRAWINGS 44 Wiring Diagram Manufactured from 8 02 Present Electrical with GFCI ...
Page 49: ...ELECTRICAL DRAWINGS 47 Wiring Diagram Mfg from 9 02 Present Electrical With Remote Disconnect ...
Page 50: ......
Page 52: ...ELECTRICAL DRAWINGS FORCE 2 Electrical Drawings Cont d ...