REPLACING BLOWER BRUSHES
Model 21025
(105 CFM)
brush replacement not recommended
Model 21024
(116 CFM)
shown
Removing old brushes:
Disconnect all
electrical cords to machine. Tip machine
upside down onto hopper. To facilitate
replacement of the blower brushes
remove blower from machine. Locate
brush clips (fig 1), using flat
screwdriver place screwdriver under brush clip as shown (fig 2), pry in an upward
motion until loose. Remove brush clip and brush assembly from motor housing
(fig 3). Remove wire connector from tab on brush assembly (fig 4).
Installing new brushes:
Push wire connector onto brush tab and ensure
connection is secure. Insert brush into housing with the tab and wire in the down
position. Slide brush assembly all the way into motor housing until it stops. Push
down and inward on brush assembly, slide brush clip into top of motor housing to
secure brush assembly (fig 5). When finished make sure the brush clip is flush or
below motor housing (fig 6).
Note: Brush clip can only be installed one way. Do not force
brush clip into motor housing or damage may occur
!
THE FORCE/2
Maintenance, Cont.
M
A
I
N
T
E
N
A
N
C
E
24
blower clip
fig 5
fig 6
fig 3
fig 4
fig 2
fig 1
Summary of Contents for FORCE/2 HP
Page 2: ......
Page 4: ...MACHINE INFORMATION 2 ...
Page 46: ...ELECTRICAL DRAWINGS 44 Wiring Diagram Manufactured from 8 02 Present Electrical with GFCI ...
Page 49: ...ELECTRICAL DRAWINGS 47 Wiring Diagram Mfg from 9 02 Present Electrical With Remote Disconnect ...
Page 50: ......
Page 52: ...ELECTRICAL DRAWINGS FORCE 2 Electrical Drawings Cont d ...