DELUXE
Inverter
Service
M
anual
15
●
★
○
Internal coil sensor
error
Internal coil sensor, main internal control panel.
16
○
★
●
Indoor fan error
Mechanical jam of fan, internal fan, main internal
control panel.
17
○
★
○
Refer to tooling
display for other
errors
Entire set of external controller.
18
●
●
★
Compressor cap
sensor error
System pressure, compressor cap sensor (protection
switch), main external control panel.
19
●
○
★
Recirculated sensor
error
Recirculated sensor, four-way valve switch error, main
external control panel.
20
○
●
★
※
Compressor
overpower
protection
Power voltage, module panel, main external control
panel.
21
○
○
★
※
Over current
protection
Power voltage, system pressure, module panel, main
external control panel.
22
●
●
○
Exhaust sensor
error
System pressure, exhaust sensor, main external control
panel.
23
●
○
●
※
Cooling
overload protection
Condenser, external fan, capillary, external coil sensor,
main external control panel.
24
○
●
●
※
Indoor high
temperature heating
protection
Evaporator, internal fan, thin unit connection pipe,
internal coil sensor, main internal control panel.
25
●
○
○
※
Indoor cooling
freezing protection
Evaporator, internal fan, capillary, internal coil sensor,
main internal control panel.
26
○
●
○
Compressor shell
temperature
protection
Same as "18 Compressor cap sensor error".
27
○
○
●
※
OVP or UPV
error
Power voltage, reactor, module panel, main external
control panel.
7-3 Troubleshooting
for Normal Malfunction
The Foremost Inspecting Items
①
The input voltage must be 10% tolerance of the rated Voltage. If it is not the case, the
air-conditioner will probably not work normally.
45