Tightening torque table
The size of pipe(mm)
Torque(N·m)
Φ6/Φ6.35
15
~
25
Φ9 /Φ9.5 2
35
~
40
Φ12/Φ12.7
45
~
60
Φ15.88
73
~
78
Φ19.05
75
~
80
Wrap the Piping
Fixing the Indoor Unit
Fixing the indoor unit
Electric Connection Requirement
●
Loosen the screws and remove from the unit.
●
Connect the cables respectively to the corresponding
terminals of the terminal board of the indoor unit (see the
wiring
diagram), and if there are signals connected to the plug, just
conduct
butt joint.
●
Ground wire: Remove the grounding screw out of the
electric
bracket, cover the grounding wire
end onto the grounding screw and screw it into the grounding
hole.
●
Fix the cable reliably with fasteners (Pressing board).
●
Put the E-parts cover back in its original place and fasten it with screws.
1. Use the insulation sleeve to wrap the joint part the
indoor unit and connection pipe,
t
hen use
insulating
material to pack and seal insulation pipe to
prevent
condensat
ion of
water on the joint
part.
2. Connect the water outlet with drain pipes, and
make the connection pipe, cables, and the drain hose
straight.
3. Use plastic cable ties to wrap the connecting pipes,
cables and drain hose. Run the pipe sloping
downward.
1. Hang the indoor unit on the peg board, and move
the unit from left to right to ensure that the hook is
properly positioned in the peg board.
2. Push toward the lower left side and the upper right
side of the unit toward the peg board, until the hook is
embedded in the slot and makes a "click" sound.