DELUXE
Inverter
Service manual
15
Mounting plate
1. The wall for installation of the indoor unit shall be hard and firm, so as to prevent vibration.
2. Use the "+" type screw to fasten the peg board,
horizontally mount the peg board on the wall, and
ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation to confirm whether it is solid
or not
.
Wall-through Hole
1. Make a hole with an electric hammer or a
water drill at the predetermined position on
the wall for piping, which shall slant outwardly by 5°-
10°.
2. To protect the piping and the cables
running through the wall from
being
damaged
by possible
rodents that may
inhabit in
the hollow wall, a pipe protecting
ring shall
be installed and sealed with putty.
Note: Usually, the wall hole i
s Φ60mm~
Φ80
mm. Avoid pre-buried power wire and hard wall when
making the hole.
Route of Pipeline
1. Depending on the position of the unit, the piping may be routed sideway
s
from left or right
( Fig 1 ), or vertically from the back( Fig 2 )(depending on the pipe length of the indoor unit). In the
case of sideway routing, cut off the outlet cutting stock of the opposite side.
2. The power cord may be routed separately from the piping. Cut off the outlet cutting
stock and then run the power cord through the hole, keeping the remaining part as
a protection from rodents.
Drain pipe connection
1. Remove the mountings and pull the indoor unit pipe out of the housing.
2.
Attach
the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the T
nut with a torque wrench
. T
he direction
is shown in
the
diagram on the right.
The torque