The minimum clearance between the air conditioner and the combustibles is 1.5 m.
The power cable enables communication between the indoor and outdoor units. You must first
choose the right cable size before preparing it for connection.
Grounding Requirements
The air conditioner is the type I electrical appliance and must ensure a reliable grounding.
Do not connect the grounding wire to a gas pipe, water pipe,lightning rod, telephone line, or a
circuit poorly grounded to the earth.
The grounding wire is specially designed and shall not be used for other purpose, nor shall it be
fastened with a common tapping screw.
Others
The connection method of the air conditioner and the power cord and the interconnection
method of each independent element shall be subject to the wiring diagram affixed to the
machine.
The model and rating value of the fuse shall be subject to the silkscreen on corresponding
controller or fuse sleeve.