2.3 LAMP INDICATIONS.
Lamp
ON
OFF
FLASHING
ZONE Lamps
1 to 16
When the Zone
is Un-sealed.
(If the "Zone
activity" option
enabled)
When the Zone
is Sealed.
FAST: *
When there has been an
Alarm / Tamper on the Zone.
SLOW: *
When the Zone has been Isolated.
AREA Lamps
A1, A2, A3, A4
Area is Armed.
(Multi-Area mode
only)
Area is Dis-armed. There has been an Alarm in the
Area.
(Multi-Area mode only)
ARM
Area/s are armed
in normal mode.
System not armed
in normal mode.
-
HOME
Area/s are armed
in home mode.
System not armed
in home mode.
-
FAULT ^
A system input is
currently in alarm.
No system inputs
are in alarm.
FAST: *
A system input has been in alarm
and must be acknowledged.
SLOW: *
When a System Input has been
Isolated.
PWR
AC mains OK
AC mains problem. -
ARM & HOME
-
-
System is in "Isolate" mode.
(NEXT, 10)
FAULT & PWR
-
-
System is in "Master Operations"
mode. i.e. NEXT functions.
0
Used to display values in programming mode.
NOTES:
^ See "Fault Analysis Lamps" in Chapter 4.6 or the "System Inputs Table".
* Alarm indication takes priority over Isolate indication.