17
Version 1.03 January-2002
1. Enter the Zone Self Test Display Mode.
If a Zone Input fails the Zone Self Test, the <FAULT> Lamp will be displayed on the Terminal.
“Fault Analysis Mode” (NEXT 25) will also display the “Zone Self Test fail” Lamp (Zone 10).
To view the Zone or Zones that have failed the Zone Self Test, Press
,
,
.
2. Note the details of any Zones that have failed the Zone Self Test.
The Zone 1 to Zone 16 Lamps will indicate any Zones that have failed the Zone Self Test so that
appropriate action may be taken. e.g. A detector fault may need to be rectified by the Installer.
3. Acknowledge the Zone Self Test fault.
Press
to acknowledge any Zone Self Test faults.
When a Zone Self Test fault has been acknowledged, the corresponding Zone Lamp will turn OFF,
and the “Zone Self Test fail” Lamp <Zone 10> in “Fault Analysis Mode” will also be cleared.
If all System Inputs have been acknowledged the <FAULT> Lamp will be turned OFF.
4.7 ZONE SELF TEST DISPLAY.
NEXT 26
LAMP
1
AC Fail.
2
Low battery.
3
Cabinet Tamper.
4
Siren monitor.
5
PWR fuse.
6
Battery fuse.
7
Comms fail.
8
System reset.
9
Keypad lockout.
10
Zone self test.
11
Keypad Medical Alarm.
12
Keypad Panic Alarm.
13
Keypad Duress Alarm.
14
Keypad Fire Alarm.
15
Door Alarm.
16
Program Change.
FAULT ANALYSIS LAMPS
FAULT ANALYSIS