22
AC-SVX002C-EN
Evaporator Piping
N
NO
OT
TIIC
CE
E
P
Prro
op
pe
err W
Wa
atte
err T
Trre
ea
attm
me
en
ntt R
Re
eq
qu
uiirre
ed
d!!
T
Th
he
e u
usse
e o
off u
un
nttrre
ea
atte
ed
d o
orr iim
mp
prro
op
pe
errlly
y ttrre
ea
atte
ed
d w
wa
atte
err
cco
ou
ulld
d rre
essu
ulltt iin
n sscca
alliin
ng
g,, e
erro
ossiio
on
n,, cco
orrrro
ossiio
on
n,, a
allg
ga
ae
e o
orr
sslliim
me
e..
U
Usse
e tth
he
e sse
errv
viicce
ess o
off a
a q
qu
ua
alliiffiie
ed
d w
wa
atte
err ttrre
ea
attm
me
en
ntt
ssp
pe
ecciia
alliisstt tto
o d
de
ette
errm
miin
ne
e w
wh
ha
att w
wa
atte
err ttrre
ea
attm
me
en
ntt,, iiff
a
an
ny
y,, iiss rre
eq
qu
uiirre
ed
d.. T
Trra
an
ne
e a
assssu
um
me
ess n
no
o rre
essp
po
on
nssiib
biilliitty
y
ffo
orr e
eq
qu
uiip
pm
me
en
ntt ffa
aiillu
urre
ess w
wh
hiicch
h rre
essu
ulltt ffrro
om
m u
un
nttrre
ea
atte
ed
d
o
orr iim
mp
prro
op
pe
errlly
y ttrre
ea
atte
ed
d w
wa
atte
err,, o
orr ssa
alliin
ne
e o
orr b
brra
acckkiissh
h
w
wa
atte
err..
N
NO
OT
TIIC
CE
E
H
He
ea
att E
Ex
xcch
ha
an
ng
ge
err D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
h
he
ea
att e
ex
xcch
ha
an
ng
ge
err d
da
am
ma
ag
ge
e..
IIff a
an
n a
acciid
diicc cco
om
mm
me
errcciia
all ffllu
ussh
hiin
ng
g sso
ollu
uttiio
on
n iiss u
usse
ed
d,,
b
by
yp
pa
assss tth
he
e E
EV
VP
P cch
hiilllle
err tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
ge
e ..
•
Evaporator water connections are grooved.
•
Thoroughly flush all water piping to the unit before
making the final piping connections to the unit.
•
Components and layout will vary slightly,
depending on the location of connections and the
water source.
•
A vent is provided at the chilled water inlet line to
the evaporator. Additional vents at high points in
the piping must be provided to bleed air from the
chilled water system.
•
Install necessary pressure gauges to monitor the
entering and leaving chilled water pressures.
•
Provide shutoff valves in lines to the gauges to
isolate them from the system when they are not in
use.
•
Use rubber vibration eliminators to prevent
vibration transmission through the water lines.
•
If desired, install thermometers in the lines to
monitor entering and leaving water temperatures.
•
Install a balancing valve in the leaving water line to
control water flow balance.
•
Install shutoff valves on both the entering and
leaving water lines so that the evaporator can be
isolated for service.
Evaporator Piping Components
Piping components include all devices and controls
used to provide proper water system operation and
unit operating safety. These components and their
general locations are given below.