Table 33.
Communication diagnostics (continued)
Diagnostic
Name
Affects
Target
Severity
Persistence
Active
Modes
[Inactive
Modes]
Criteria
Reset
Level
Comm Loss:
Evaporator
Water Pump 1
Relay
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evaporator
Water Pump 2
Relay
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evaporator
Pump 1 Fault
Input
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evaporator
Pump 2 Fault
Input
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evap Pump
Inverter 1 Run
Command
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evap Pump
Inverter 1 Fault
Input
Chiller
Warning
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evap Pump
Inverter 1
Frequency
Feedback
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Evap Pump
Inverter 1
Speed
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Comm Loss:
Suction
Temperature
Circuit
Immediate
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Electronic
Expansion
Valve
Circuit
Immediate
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
External Noise
Reduction
Request Input
Chiller
Warning and
Special Action
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period. External input is excluded from arbitration
logic per standard arbitration rules.
Remote
Comm Loss:
Energy Meter
Pulse Input
Chiller
Warning
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Phase
Protection
Fault Input
Chiller
Normal
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote
Comm Loss:
Discharge
Temperature
Sensor
Circuit
Immediate
Latch
All
Continual loss of communication between the MP and
the Functional ID has occurred for a 35-40 second
period.
Remote