IPC offline alarm: Once you select this item, system can
generate an alarm when the front-end IPC disconnects with
the local NVR. The alarm can activate record, PTZ, snap
and etc. The alarm can last until the IPC and the NVR
connection resumes.
z
Enable: Please you need to highlight this button to enable
current function.
z
Type: normal open or normal close.
z
Period: It is to set local alarm period. System only enables
local alarm in the specified period. Click the Set button;
you can select the business day and the non-business day.
Please note for the work day/free day setup and the
specific work day setup, system just saves the latest setup.
For example, the work day ranges from 8:30-17:30
Monday to Friday, and then you set the period 7:10-18:00
for Monday. So, the arm period of the Monday ranges from
7:10 to 18:00. Please highlight the corresponding button to
enable this function.
z
PTZ activation: When an alarm occurred, system can
activate the PTZ operation. The PTZ activation lasts an
anti-dither period.
In the Pan/Tilt/Zoom interface (Main menu->Setting->
Pan/Tilt/Zoom), please set video channel, speed dome
protocol and etc.
Select the channel of current speed dome as current
monitor video and the right click mouse to select
Pan/Tilt/Zoom item. Now you can set preset, tour pattern.
In Figure 5-55, click “select” button, you can see an
interface is shown as in Figure 5-56. Here you can set the
activation operation such as preset tour, pattern and enable.
z
Anti-dither: Here you can set anti-dither time. The value
ranges from 5 to 600s. The anti-dither time refers to the
alarm signal lasts time. It can be seem as the alarm signal
activation stays such as the buzzer, tour, PTZ activation,
snapshot, channel record. The stay time here does not
include the latch time. During the alarm process, the alarm
signal can begin an anti-dither time if system detects the
local alarm again. The screen prompt, alarm upload, email
and etc will not be activated. For example, if you set the
anti-dither time as 10 second, you can see the each
activation may last 10s if the local alarm is activated.
During the process, if system detects another local alarm
signal at the fifth second, the buzzer, tour, PTZ activation,
snapshot, record channel will begin another 10s while the
screen prompt, alarm upload, email will not be activated
again. After 10s, if system detects another alarm signal, it
can generate an alarm since the anti-dither time is out.
z
Alarm output: The number here is the device alarm output
port. You can select the corresponding ports(s) so that
system can activate the corresponding alarm device(s)
when an alarm occurred.
z
Latch: When the anti-dither time ended, the channel alarm
you select in the alarm output may last the specified period.
The value ranges from 1 to 300 seconds. This function is
not for other alarm activation operations. The latch is still
valid even you disable the alarm event function directly.
z
Show message: System can pop up a message to alarm you
in the local host screen if you enabled this function.
z
Alarm upload: System can upload the alarm signal to the
network (including alarm centre and the WEB) if you
enabled current function. System only uploads the alarm
channel status. You can go to the WEB and then go to the
Alarm interface to set alarm event and alarm operation.
Please go to the Network interface to set alarm centre
information.
z
Send email: System can send out the alarm signal via the
email to alert you when alarm occurs. Once you enable the
snap function, system can also send out an image as the
attachment. Please go to the Main Menu->Setting
->Network->Email interface to set.
z
Record channel: you can select proper channel to record
alarm video (Multiple choices).
You need to set alarm record mode as Schedule in Record
interface (Main Menu->Advanced->Record). Please note
the manual record has the highest priority. System record
all the time no matter there is an alarm or not if you select
Manual mode.
Now you can go to the Schedule interface (Main
Menu->Setting->Schedule) to set the record type,
corresponding channel number, week and date. You can
select the record type: Regular/MD/Alarm/MD&Alarm.
Please note, you can not select the MD&Alarm and MD (or
Alarm) at the same time.
Now you can go to the Encode interface to select the alarm
record and set the encode parameter (Main
Menu->Setting->Encode).