4.3.12.14 CLSP Output Mapping
This register maps the various internal signals to CLSP camera output.
Address
:
0x05A4
Data (3:0)
:
0000 – no mapping
0001 – exposure start
0010 – exposure end
0011 – mid exposure
0100 – active exposure window
0101 – H sync
0110 – V sync
0111 – odd/even frame flag
1000 – trigger pulse actual
1001 – trigger pulse delayed
1010 – camera ready
1011 – pulse generator
1100 – strobe #1
1101 – strobe #2
Others – reserved
Data (31:4)
:
N/A
4.3.12.15 Strobe #1 Select
This register sets the Strobe #1 mode of operation.
Address
:
0x055C
Data (1:0)
:
00 – disable Strobe #1
01 – enable Strobe #1 each frame
10 – enable Strobe #1 odd frames only
11 – enable Strobe #1 even frames only
Data (31:2)
:
N/A
4.3.12.16 Strobe #1 Position
This register sets the position of the strobe #1 pulse with respect of the end of
the frame.
Address
:
0x0568
Data (23:0)
:
<value> – strobe #1 pulse positions in microseconds
Data (31:24)
:
N/A
4.3.12.17 Strobe #2 Select
This register sets the Strobe #2 mode of operation.
Address
:
0x0560