BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 1.0
6421 Congress Ave.
5/4/2010
Boca Raton, FL 33487
+1 (561) 989-0006
147 of 212
1010 – camera ready
1011 – pulse generator
1100 – strobe #1
1101 – strobe #2
Others – reserved
Data (31:4)
:
N/A
4.3.12.11OUT2 Output Polarity
This register sets the polarity (active Low or High) for the OUT2 output.
Address
:
0x0598
Data (0)
:
0 – active LOW
1 – active HIGH
Data (31:1)
:
N/A
4.3.12.12OUT2 Output Mapping
This register maps the various internal signals to OUT2 camera output.
Address
:
0x059C
Data (3:0)
:
0000 – no mapping
0001 – exposure start
0010 – exposure end
0011 – mid exposure
0100 – active exposure window
0101 – H sync
0110 – V sync
0111 – odd/even frame flag
1000 – trigger pulse actual
1001 – trigger pulse delayed
1010 – camera ready
1011 – pulse generator
1100 – strobe #1
1101 – strobe #2
Others – reserved
Data (31:4)
:
N/A
4.3.12.13 CLSP Output Polarity
This register sets the polarity (active Low or High) for the CLSP (Camera
Link cable Spare) output.
Address
:
0x05A0
Data (0)
:
0 – active LOW
1 – active HIGH
Data (31:1)
:
N/A