This register selects the trigger signal de-bounce time. Any subsequent trigger
signals coming to the camera within the de-bounce time interval will be
ignored.
Address
:
0x0510
Data (1:0)
:
00 – no de-bounce
01 – 0.1 ms de-bounce time
10 – 1.0 ms de-bounce time
11 – 10.0 ms de-bounce time
Data (31:2)
:
N/A
4.3.9.6 Trigger Overlap
This register selects the trigger overlap mode. If the camera receives a trigger
pulse while the camera is still processing the previous trigger, the user has the
option to ignore the incoming trigger or to terminate the previous process and
to start a new one.
Address
:
0x0514
Data (1:0)
:
00 – ignore the next trigger
01 – accept only after the exposure is completed
10 – accept at any time
11 – N/A
Data (31:2)
:
N/A
4.3.9.7 Triggering Mode Selection
This register selects the triggering mode.
Address
:
0x0518
Data (3:0)
:
0x0 – standard triggering
0x1 – fast triggering
0x2 – double triggering
0x3 – frame accumulation
0x4 – asynchronous triggering
0x5 to 0xF – reserved
Data (31:4)
:
N/A
4.3.9.8 Number of Frames Captured
This register selects the number of frames captured after each trigger signal.
Address
:
0x051C
Data (15:0)
:
<value> – # of frames captured
Data (31:16)
:
N/A
4.3.9.9 Number of Pulses Used