4.3.4.11
Current Camera Temperature
This register returns the current camera temperature in degrees Celsius. The
temperature resolution is 0.25°C – Table 3.1.
Address
:
0x6010
Data (9:0)
:
<Current Camera Temperature>
Data (31:10)
:
N/A
Temperature
Register Value
+127.75 °C
01 1111 1111
...
...
+0.25 °C
00 0000 0001
0° C
00 0000 0000
-0.25 °C
11 1111 1111
...
...
-128 °C
10 0000 0000
Table 3.1 – Current camera temperature values
4.3.5 Image Size (AOI) Workspace Registers
4.3.5.1 Scan Mode Control
This register sets the current CCD readout (scan) mode. The default CCD
scanning mode for all Bobcat cameras is progressive, where all pixels within
the same exposure period are read out simultaneously. Some CCD imagers
allow a sub-sampled scan (center only), where only a sub-section of the pixels
are readout, thus providing a higher camera frame rate.
Address
:
0x0504
Data (0)
:
0 – normal – progressive scan
1 – center – sub-sampled (partial) scan
Data (31:1)
:
N/A
4.3.5.2 Vertical Binning Mode
This register sets the current binning format in vertical direction. Five possible
vertical binning options are possible.
Address
:
0x0500
Data (2:0)
:
000 – 1x vertical binning
001 – 2x vertical binning
010 – 3x vertical binning
011 – 4x vertical binning
100 – 8x vertical binning
Data (31:3)
:
N/A