![Imperx BOBCAT ICL-B0610C Hardware User Manual Download Page 141](http://html1.mh-extra.com/html/imperx/bobcat-icl-b0610c/bobcat-icl-b0610c_hardware-user-manual_2049008141.webp)
BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 1.0
6421 Congress Ave.
5/4/2010
Boca Raton, FL 33487
+1 (561) 989-0006
141 of 212
This register selects the number of trigger pulses used during a single trigger
sequence in frame accumulation mode.
Address
:
0x0520
Data (15:0)
:
<value> – # of pulses used
Data (31:16)
:
N/A
4.3.9.10
Trigger Exposure Delay
This register selects the delay between the trigger signal and the beginning of
exposure. The actual exposure can set using “Exposure Time Absolute”
register 0x0548.
Address
:
0x0528
Data (23:0)
:
<value> – exposure delay in microseconds
Data (31:24)
:
N/A
4.3.9.11
Trigger Strobe Enable
This register enables a strobe signal synchronous with the trigger pulse. The
strobe signal is mapped to one or both of the available strobe outputs.
Address
:
0x0524
Data (1:0)
:
00 – no strobe signal
01 – enable Strobe #1
10 – enable Strobe #2
11 – enable Strobe #1 and Strobe #2
Data (31:2)
:
N/A
4.3.9.12 Trigger Strobe Position Delay
This register sets the delay between the trigger pulse and the strobe pulse.
Address
:
0x052C
Data (23:0)
:
<value> – trigger strobe delay
Data (31:24)
:
N/A
4.3.9.13 Trigger Strobe Pulse Duration
This register sets the strobe pulse duration.
Address
:
0x05B8
Data (23:0)
:
<value> – trigger strobe duration
Data (31:24)
:
N/A