Getting Started
29
Caution
These power splitting cables are provided so that the system is operated from a SINGLE power source
thus providing a single point of disconnect.
3
A STANDBY LED on the ESI/Ops Panel indicates whether AC Mains power is present.
Caution
The power connections must always be disconnected prior to removal of the Power Supply module from
the enclosure.
2.11 Grounding Checks
Perform these checks to ensure that a safe grounding system is provided:
• If a rack distribution system is being used.
–
Ensure power is removed from the rack.
–
Connect the supplied power cord to the rack distribution and the enclosure.
• If a direct connection is made with the power cord, ensure that it is connected to the enclosure.
Warning
Some electrical circuits could be damaged if external signal cables or power control cables are
present during the grounding checks.
• Check for continuity between the earth pin of the power cord on one of the Power Supply modules
(or rack inlet) and any exposed metal surface of the RS-0800-LVD enclosure.