Introduction
5
Optionally, a second Power Supply plug-in module can be fitted.
PSU voltage operating ranges are nominally 115V or 230V, selected automatically.
Two LEDs are mounted on the front panel of the Power Supply module (see
Figure 1–4
). To indicate the
status of the PSU.
1.3.1.1
Multiple Power Supply Modules
If you have two Power Supply modules fitted, they operate together. If one fails the other maintains the
power supply while you replace the faulty unit.
Important
Module replacement should only take a few minutes to perform but must be completed within 10
minutes from removal of the failed module. Alternatively, if there is no replacement module
available, a Power Supply blanking module could be fitted after removing the faulty module.
1.3.1.2
Power Supply Indicators
PSU Panel
1.3.2 Cooling Modules
One Cooling module is supplied mounted in the rear of the enclosure as part of the subsystem core
product (
Figure 1–9
).
Figure 1–8
PSU LEDs
Table 1–1
PSU LEDs
LED
Definition
Normal
Fault
Green
Power Output
ON
OFF
Amber
PSU/Fault
OFF
ON