Active Alarms
The
Active Alarms
tab groups and displays all alarms for a given Element , and you can expand or
collapse the view.
Details are provided on the Type of the alarm, the Time, Reason, and Priority.
Element
SNP device that originated the alarm
Location
The location of the alarm within the device, which will be one of the following:
•
Processor_Section_ Program_ (where the specific processor letter, section
number, and program number are defined)
•
System/Subsystem (for system-level alarms)
Time Issued
When the alarm originated
Alarm
The name of the alarm
Reason
Why the alarm was triggered
Priority
1-4 is a minor alarm; 5-10 is a major alarm
Disable
Disable/enable an alarm directly from the Active Alarm overlay.This button does
not appear when a user is assigned to the Viewers group.
Click on a column header to sort by that column.
Alarm Log
The
Alarm Log
tab lets you select an Element from a drop down list and then view its log, clear it,
refresh it, or export it as a CSV file. In addition to the details for an alarm that are listed on the Active
Alarms tab, the Alarm Log also displays the following statistics:
•
Count
: How many times the alarm has triggered