Important Points
•
Before you begin cleaning, always inspect the fiber connections.
•
Inspect and clean both fiber ends every time you make a connection.
•
Keep a protective cap on unplugged fiber connectors.
•
Do not touch the end of a fiber.
•
Store unused protective caps in a clean resealable container, located nearby for easy access.
•
Do not reuse cleaning tissues or swabs.
•
Do not allow alcohol or another wet cleaning agent to dry on a fiber end.
•
Never touch the dispenser tip of an alcohol bottle or any clean portion of a tissue or swab.
•
Use care when handling the fiber; do not twist or pull.
•
Keep your cleaning fluids away from open flame or spark.
The illustration shows the acceptable limits of defects in a fiber connection.
Figure 9:
Fiber Optic Cross-Section
Inspection Procedure
To inspect and clean the fibers, follow these steps:
1.
Ensure the fiber is not "live."