background image

Preface

Safety

x

Copyright © 2011, Harris Corporation

Restriction on Hazardous Substances (RoHS) Compliance

Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on
Hazardous Substances (RoHS)—sets limits on the use of certain substances found in
electrical and electronic equipment. The intent of this legislation is to reduce the amount of
hazardous chemicals that may leach out of landfill sites or otherwise contaminate the
environment during end-of-life recycling. The Directive, which took effect on July 1, 2006,
refers to the following hazardous substances:

„

Lead (Pb)

„

Mercury (Hg)

„

Cadmium (Cd)

„

Hexavalent Chromium (Cr-V1)

„

Polybrominated Biphenyls (PBB)

„

Polybrominated Diphenyl Ethers (PBDE)

According to this EU Directive, all products sold in the European Union will be fully
RoHS-compliant and “lead-free.” (See our website for more information.) Spare parts
supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from
the legislation. Equipment that complies with the EU directive will be marked with a
RoHS-compliant emblem, as shown in

Figure 1-1

.

Figure 1-1

RoHS Compliance Emblem

Waste from Electrical and Electronic Equipment (WEEE) Compliance

The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic
Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical
and electronic waste products. The objective of the WEEE Directive is to assign the
responsibility for the disposal of associated hazardous waste to either the producers or users
of these products. As of August 13, 2005, the producers or users of these products were
required to recycle electrical and electronic equipment at end of its useful life, and may not
dispose of the equipment in landfills or by using other unapproved methods. (Some EU
member states may have different deadlines.)

In accordance with this EU Directive, companies selling electric or electronic devices in the
EU will affix labels indicating that such products must be properly recycled. (See our website
for more information.) Contact your local sales representative for information on returning
these products for recycling. Equipment that complies with the EU directive will be marked
with a WEEE-compliant emblem, as shown in

Figure 1-2

.

Summary of Contents for Selenio 6800+

Page 1: ...Selenio 6800 Satellite Receiver and Demodulator with Conditional Access Edition A 175 100445 00 Delivering the Moment Installation and Operation Manual...

Page 2: ...io InfoCaster Player Nexio InfoCaster Tra c Nexio InstantOnline Nexio mCAPTURE Nexio NewsForce Nexio NXIQ Nexio Playlist Nexio Remote Nexio RTX Net Nexio TitleMotion Nexio TitleOne Nexio Velocity ESX...

Page 3: ...SRC6800 Satellite Receiver and Demodulator with Conditional Access Installation and Operation Manual November 2011 Edition A...

Page 4: ......

Page 5: ...rface 1 Overview 1 Product Description 1 Demultiplexing 1 Unreferenced PIDs 1 RF Inputs 1 ASI Outputs 2 ASI Input 2 10 100 BaseT Ethernet 2 Conditional Access 2 Module Description 3 SRC6800 Front Modu...

Page 6: ...mmand Parameters 21 Overview 21 SRC6800 Parameters 22 How To Use Telnet 22 Parameter Usage Notes 22 Parameters 23 Configuration Parameters 23 Status Parameters 27 Alarms 28 Chapter 6 Specifications 31...

Page 7: ...SRC6800 Installation and Operation Manual v Copyright 2011 Harris Corporation Module Does Not Seem to Work 35 Contacting Customer Service 36...

Page 8: ...Contents vi Copyright 2011 Harris Corporation...

Page 9: ...his manual adheres to the following writing conventions Table P 2 Writing Conventions Term or Convention Description Bold Indicates dialog box property sheet field button check box list box combo box...

Page 10: ...cept for certain designated options as described in this manual all hardware upgrades modifications or repairs require you to return the product to the Customer Service center Returning a Product In t...

Page 11: ...in the rack If this product has a provision for external earth grounding it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel IMPORTANT Only qualifi...

Page 12: ...with a RoHS compliant emblem as shown in Figure 1 1 Figure 1 1 RoHS Compliance Emblem Waste from Electrical and Electronic Equipment WEEE Compliance The European Union EU Directive 2002 96 EC on Wast...

Page 13: ...SRC6800 Installation and Operation Manual xi Copyright 2011 Harris Corporation Figure 1 2 WEEE Compliance Emblem...

Page 14: ...Preface Safety xii Copyright 2011 Harris Corporation...

Page 15: ...n IP solution When used with an MFD6800 these two modules provide a complete Satellite to H 264 or MPEG 2 Video Decode solution Product Description The SRC6800 Satellite Receiver and Demodulator is pa...

Page 16: ...outputs 10 100 BaseT Ethernet The Ethernet interface is provided for control The SRC6800 supports CCS Telnet and HTTP control through this interface Conditional Access The SRC6800 also includes a cond...

Page 17: ...onal Green The module is powered ON The module is operating properly Red The module is either booting or experiencing an error Red blinking The module has booted in safe mode See Toggle Switch descrip...

Page 18: ...state of the ASI Input Off The Interface is not configured for use Green The interface is active and operating normally Red The interface is experiencing a Loss of Signal LOS Amber The interface is ex...

Page 19: ...Connector Table 1 2 SRC6800 Back Connector Electrical Interfaces Ite m Description Full Description 1 4 RF Inputs Hard wire RF inputs to up to four different sources and use software selection to dete...

Page 20: ...filler plate must be installed immediately to the right of the SRC6800 to accommodate power requirements ASI In This interface allows demultiplexing and decryption of a transport stream originating o...

Page 21: ...o 100 meters in length may be used to link the system to a hub The and polarities must be wired correctly for proper operation Table 1 3 10 100 BaseT Ethernet Pin Assignments Pin Signal Description 1...

Page 22: ...Chapter 1 SRC6800 Module and Interface 8 Copyright 2011 Harris Corporation...

Page 23: ...RC6800 installation process See the FR6802 Frame Installation and Operation Manual for information about installing and operating a 6800 frame and its components Maximum 6800 Frame Power Ratings Table...

Page 24: ...for servicing Module Installation Required Frames and Back Connector Types The SRC6800 module has a double width back connector that can be installed in a 6800 XF See the 6800 Frame Installation and...

Page 25: ...er the IP Address of the 6800 series shelf in the Host IP field b Click the Options button to open the Communication Settings dialog c Choose the Point to Point option from the Communication Type drop...

Page 26: ...Chapter 2 Installation and Navigation Discovery 12 Copyright 2011 Harris Corporation...

Page 27: ...he toggle switch back to the center position Procedure 1 Install the appropriate upgrade package from the CD ROM or download it from one of these Harris web sites http www broadcast harris com support...

Page 28: ...close the File Selection dialog and to populate the full path name to the upgrade zip package Note The extraction process on the ZIP file is handled as part of the upgrade process There is no need to...

Page 29: ...ffers two mechanisms the Log Tab and the Progress Tab for determining the status of an upgrade once it has begun 1 The Progress Tab provides a table with one row identifying each device scheduled to r...

Page 30: ...011 Harris Corporation Figure 3 4 Software Upgrade Dialog s Progress Tab In the event of a failure of any kind double click on the row indicating the failure to open the Log Scroll down to the bottom...

Page 31: ...follows 1 Select the Configuration branch 2 Select the Network branch 3 Choose the IP Address parameter 4 Set the IP Address parameter to 123 123 123 123 See the RCP CCS 1U Remote Control Panel manua...

Page 32: ...t Stream Output on page 19 How to Configure an RF Input Source Use these steps to extract a single or a multiple program transport stream from a signal entering the system through its RF input 1 Confi...

Page 33: ...ion DMX Output All Choose Program to extract only a particular program from the MPTS Configuration DMX Output Program 2 Specify the program number of the program to extract or alternatively enter a ne...

Page 34: ...s SRC6800 s Module Status LED illuminates red when an alarm condition is present Navigator can be used to monitor an SRC6800 module Alarms messages are aggregated and presented in a manner that distin...

Page 35: ...e interface or telnet use a slash as a separator instead of and include a separator before the parameter name SRC6800 Commands are arranged into three groups Configuration Commands Use these commands...

Page 36: ...e and password The following username and password are factory defaults username admin password admin Once a Telnet connection is established commands listed in the following sections can be directly...

Page 37: ...sk 1 2 DVB S2 QPSK1 2 mod s2 qpsk 3 5 DVB S2 QPSK3 5 mod s2 qpsk 2 3 DVB S2 QPSK2 3 mod s2 qpsk 3 4 DVB S2 QPSK3 4 mod s2 qpsk 4 5 DVB S2 QPSK4 5 mod s2 qpsk 5 6 DVB S2 QPSK5 6 mod s2 qpsk 8 9 DVB S2...

Page 38: ...ar hex Encrypted Session Word Specifies the BISS Encrypted Session Word ESW An encrypted session word should be set to a 16 character hexadecimal string upper case and lower case letters allowed such...

Page 39: ...read the value receive the 14 character string 14 char hex Enable Enables BISS Enable Disable Disable Configuration Dmx Input Specifies the active input interface ASI RF ASI RF Select Specifies the R...

Page 40: ...nd only the unreferenced PIDs if any are put into the output stream When Program number is zero and Output is set to All all programs are decrypted and put out All Program All Output Rate Mbps Specifi...

Page 41: ...d Path Description Options Default Status Dmx Transport Stream Present Indicates whether a transport stream is present Present Not Present N A Transport Stream Rate Mbps Indicates the transport stream...

Page 42: ...lost negotiating 10h 10f 100h 100f 100 RX Packets Indicates the number of packets received in the last second Counter TX Packets Indicates the number of packets transmitted in the last second Counter...

Page 43: ...icates the specified program is not present on the demux interface True False Input Overflow This alarm state is raised when the demultiplexer s input overflow status counter begins to increment True...

Page 44: ...Chapter 5 Command Parameters 30 Copyright 2011 Harris Corporation...

Page 45: ...Applicable Standards DVB ASI A011 Rev 1 0 L Band Interfaces Connectors F Type Baud Rate L Band Frequency Range 0 9400 2 150 GHz Input Impedance 75 Ohm Maximum Total Input Power 25 dBm Minimum Signal L...

Page 46: ...This module requires a two slot width Back Connector see below 3 33 cm 1 31 in Weight 0 13 kg 0 28 lbs Back Connector Height Fits 2RU 6800 series frames 7 7 cm 3 0 in Depth Excluding cable allowances...

Page 47: ...ation for answers to your question The following information can be found in the Support Section of our website http broadcast harris com Product manuals Online Help Application Notes Errata Product R...

Page 48: ...le Unscrew and remove the back module Inspect the 20 or 30 pin spring connector at the bottom of the back module and verify that the connector does not have any slightly bent or pressed pins Carefully...

Page 49: ...ttings correctly the Frame ID DIP switch is located at the rear of the frame If only one frame is connected set the DIP switch to 00 If multiple frames are used in a daisy chain set the DIP switch num...

Page 50: ...s not possible contact Customer Support Note Pressed pins are ok and will not affect the functionality Contacting Customer Service We are committed to providing round the clock 24 hour service to our...

Page 51: ...odule not found 34 Module Status LED 3 Not ready status 34 O Outputs ASI 2 P Q Parameters Configuration 23 Status 27 Power consumption 32 dissipation 9 Power ratings 9 Precautions safety ix Product de...

Page 52: ...Copyright 2009 2010 Harris Corporation Index 2 U Unpacking information viii Usable slots 9 W Z Web site location of manuals viii WEEE compliance x...

Page 53: ......

Page 54: ...s and tradenames are the property of their respective companies 2012 Harris Corporation Broadcast Communications Division 25 Dyas Road North York ON CANADA M3B 1V7 Tel 416 445 9640 www broadcast harri...

Reviews: