DRAIN WORK
While the Air-Water Heat Pump is running in heating mode, Ice can begin accumulating on the surface of the condenser.
To prevent Ice from growing, the system goes into De-frost mode, and then Ice on the surface changes to water.
Dropped water from the condenser shall be eliminated through running drain holes to prevent Ice from growing at low
temperatures.
In case there is not enough space for drainage out of the unit,
Additional drain works are required. Follow the description below.
Make space more than 100mm between the bottom of the outdoor unit and the
ground for the installation of the drain hose.
Insert the drain plug into the hole at the bottom of the outdoor unit.
Connect the drain hose to the drain plug.
Make sure dust or small branches should not go into the drain hose.
If drain work is not enough, it can lead to
system performance
degradation and system damage.