11
UNIT SPECIFICATION (without water tank)
Units
6 kW
9 kW
12 kW
16 kW
Air-water used
Nominal Heating capacity/ COP (A7/W35)
1)
kW/ W/W
6,0/ 4,92
9,0/
4,81
12,0/ 4,63
16,0/ 4,26
Nominal Heating capacity/ COP (A2/W35)
2)
kW/ W/W
5,2/ 3,51
7,7/ 3,41
12,79/ 3,49
15,93/3,26
Nominal Heating capacity/ COP (A-7/W35)
3)
kW/ W/W
5,5/ 2,75
7,9/ 2,72
11,77/2,41
14,38/ 2,22
Nominal Heating capacity/ COP (A7/W45)
4)
kW/ W/W
5,4/ 3,58
8,6/ 3,69
11,50//3,56
15,30/3,37
Nominal Heating capacity/ COP (A7/W55)
5)
kW/ W/W
4,80/ 2,65
8,0/ 2,93
11,01/2,87
14,60/2,74
Nominal Cooling capacity/ EER (A35/W18)
6)
kW/ W/W
6,5/ 4,42
8,7/ 4,12
12,0/3,87
15,0/3,62
Seasonal enr
. efficiency ƞ
s
LWT 35
°
C/ 55
°
C
ETA %
180/129
175/ 127
181/122
175/121
Outdoor units
Water Flow Rate (35
°
C)
m
3
/h
1.04
1.56
2.1
2.76
Water Flow Rate (55
°
C)
m
3
/h
0.57
0.87
1,17
1,54
Ambient Temperature, Heating
°C
from -25 to +35
Ambient Temperature, Cooling
°C
from +10 to +46
Ambient Temperature, DHW
°C
from -25 to +43
Compressor Type
BLDC Twin Rotary
Refrigerant Type
kg
R32
R410A
Refrigerant Factory Charging
kg
0,81
0,95
2,98
Dimensions (height x width x depth)
mm
638x810x310 998x940x330
1420x940x330
Weight (without packaging)
kg
46,5
72
109
Power network connection values
Electrical connections
1F 220÷240V/ 50Hz
3F 400V/ 50Hz
Compressor rated power, Heating (A7/W35)
1)
kW
1,22
1,87
2,59
3,76
Compressor rated power, Heating (A7/W35)
5)
kW
1,81
2,73
3,7
5,38
Compressor rated power, Cooling (A7/W35)
6)
kW
1,47
2,11
3,10
4,14
Max. current with inrush current limiter
A
20
27,5
16,1
16,1
Piping Connections
Liquid Pipe Connections
mm
6,35
6,35
9,52
9,52
Gas Pipe Connections
mm
15,88
15,88
15,88
15,88
Max.[Equiv.] Piping length (ODU-IDU)
m
30
35
50
50
Indoor units
Ambient Temperature
°C
from +5 to +35
Min. flow temperature
°C
15
Max. flow temperature
7)
°C
65
Dimensions (height x width x depth)
mm
640x535x481
Weight (without packaging)
kg
54
56
58
60
Electric heater power
kW
3 / 6 / 9
1) A2W Condition: (Heating) Water In/Out 30
℃
/35
℃
, Outdoor Air 7
℃
[DB]/6
℃
[WB]
2) A2W Condition: (Heating) Water In/Out 30
℃
/35
℃
, Outdoor Air 2
℃
DB
3) A2W Condition: (Heating) Water In/Out 30
℃
/35
℃
, Outdoor Air -7
℃
DB
4) A2W Condition: (Heating) Water In/Out 40
℃
/45
℃
, Outdoor Air 7
℃
DB
5) A2W Condition: (Heating) Water In/Out 47
℃
/55
℃
, Outdoor Air 7
℃
DB
6) A2W Condition: (Cooling) Water In/Out 23
℃
/18
℃
, Outdoor Air 35
℃
[DB].
7) 65°C down to +10°C (max. 60°C down to -5°C)
Summary of Contents for Inuit 6I
Page 1: ...5 INSTALLATION MANUAL AIR TO WATER HEAT PUMP IGLU INUIT...
Page 16: ...16 IGLU Inuit 6WTI indoor unit...
Page 17: ...17 IGLU Inuit 9I outdoor unit IGLU Inuit 9I indoor unit...
Page 18: ...18 IGLU Inuit 9WTI outdoor unit IGLU Inuit 9WTI indoor unit...
Page 19: ...19 IGLU Inuit 12I IGLU Inuit 16I outdoor unit IGLU Inuit 12I IGLU Inuit indoor unit...
Page 27: ...27 SPACE REQUIREMENTS FOR OUTDOOR UNIT WHEN INSTALLING ONE OUTDOOR UNIT...
Page 43: ...43...